3.

 

Safety advices 

 

 

The remote control corresponds to the appropriate safety regulations. 

 

 

 

DANGER

 

Danger to life due to electric shock! 

 

Only trained, competent and authorised persons (electrical technician according to DIN VDE 
1000-10 and BGV A3) are allowed to do mounting, electrical installation and commissioning, 
maintenance and repair work at the remote control! 

 

Follow all local regulations of the responsible energy service providers! 

 

Ensure that the power supply is switched off and that the remote control cannot be switched on 
before starting installation or repair work on electrical equipment. 

 

Never work on current conducting parts! 

 

 

!

 

Attention! 

 

Never bring easily inflammable materials near to the remote control! 

 

Protect the remote control against humidity, coldness, heat, dust and strong sunlight! 

 

The remote control may be damaged, even if it falls down of a low height! 

 

The remote control is only allowed to be operated in perfect technical condition. Damages, that 
affect safety or the proper functioning of the remote control, have to be removed at once by com-
petent and authorised persons! 

 

4.

 

Warranty and liability 

 

 

All regulations about warranty and liability are defined in the general terms and conditions of the manufacturer 
or in the particular contractual relationship. Warranty and liability claims are generally excluded in these cases: 

 

if damages result of inappropriate use of the remote control 

 

if the housing had been opened unauthorised, unauthorised structural modifications or adjustments on the 
controller software had been implemented 

 

if the electrical technician had executed mounting or repair work improperly 

 

if safety advices or instructions of the operating or the commissioning manual had been ignored 

 

5.

 

Location of the manual 

 

 

This operating and commissioning manual has to be handed out to the technician before mounting work is 
started. It has to be stored in readable condition near to the remote control in order to ensure quick access if 
needed. 

 

6.

 

Transport and storage 

 

 

 

Prove carefully, if there are damages at the packaging or at the remote control. 

 

Only transport the remote control in the original packaging. 

 

The remote control may be damaged, even if it falls down of a low height. 

 

Avoid hits or shocks and extreme temperatures during transport and storage (below 0 °C, above  
+ 50 °C). 

 

The remote control may only be storaged in the original packaging and in dry surrounding areas. 

Safety advices 

Summary of Contents for DFW HZR

Page 1: ...Page 1 OPERATING AND COMMISSIONING MANUAL...

Page 2: ...cal connection of the remote control at the heating controller 5 9 Disassembly and disposal 6 10 Your digital remote control is structured like this 6 11 Functions and adjustments 7 11 1 Basic informa...

Page 3: ...t wall construction housing 1 2 Technical data Connection eBus max 24 V 50 mA DC 2wire connection pole independent Sensors NTC temperature sensors 8 2 k at 25 C Protection degree IP 20 according to DI...

Page 4: ...d liability All regulations about warranty and liability are defined in the general terms and conditions of the manufacturer or in the particular contractual relationship Warranty and liability claims...

Page 5: ...ply of the heating controller every time before the clamp cover is opened Make sure that the controller cannot be switched on DNAGER Connect the remote control to the heating controller Use a 2 wire w...

Page 6: ...lectronic equipment act or ElektroG 10 Your digital remote control is structured like this Your remote control has a clearly arranged display which indicates information e g about actual tempera tures...

Page 7: ...e always priority to the adjustments at the heating controller Please also consider the operating and the commissioning manual of the heating controller for all works and adjustments at your digital r...

Page 8: ...re During the data transfer adjustments via the keys are blocked That means you have to wait until the data transfer has been completed if you want to change values 11 5 Leave a submenu With the key y...

Page 9: ...0 3 Max 3 0 1 2 Steepness 2 heating circuit As steepness 1 heating circuit Only adjustable in configuration 5 or 6 No 2 Min 0 3 Max 3 0 1 2 P value 1 heating circuit Proportional range Only adjustable...

Page 10: ...ating mode day OFF or day night When adjusting this operating mode you are asked to enter a start date and an end date OFF Heating and hot water support are off Only hot water The hot water support ru...

Page 11: ...n the controller The cursor below the symbol of the adjusted operating mode flashes Manual change to tem perature regulation econ omy level In this mode you leave the automatic temperature regulation...

Page 12: ...ystem and its configuration which sensors are mounted at your heating system For this reason it is possible that your controller does not display all values that are shown in the following chart Comin...

Page 13: ...ction Factory setting Range Your setting 1 Controller address 1 1 8 2 Controller type only display 3 HZR C 2 HZR E 3 Controller configuration only display 1 8 E3 2 Correction value No Action Factory s...

Page 14: ...nformation on the display check if the device is connected correctly 3 Check if there is an error that is described in the commissioning manual of the heating controller Replace the digital remote con...

Page 15: ...Page 15 Notes...

Page 16: ...ng manual is not allowed to be duplicated distributed altered transferred and translated into another language or to be used otherwise The information in this oper ating and commissioning manual has b...

Reviews: