83-515-000 Rev. A
62
Retransmit last
message
110x xxxx
Last message Retransmit last response from a
command. x xxxx is the address of
the supply in binary.
Acknowledge
SRQ
111x xxxx
None
Acknowledge SRQ. If retransmission
of SRQ is enabled, it will remain en-
abled for the next SRQ. X xxxx is the
address of the supply in binary.
Test if MD Mode
is Installed
Byte 1
1010 1010
Byte 2
xxxx xxxx
0 or 1
Returns a 0 if not installed or a 1 if
installed. A ‘$’ sign followed by a 2
bytes checksum and Carriage Return
is appended to the data. xxxx xxxx is
the address of the supply in binary.
Supply Initiated
Communications
SRQ 100x
xxxx N/A
SRQ from supply when in MD Mode.
X xxxx is the address of the supply in
binary.
Table 7-4. SINGLE BYTE COMMANDS
Table 7-5: Voltage programming range
NOTE:
The power supply can accept values higher 5% than the table
values, however it is not recommended to program the power
supply beyond the rated values.
Table 7-6: Current programming range
Model
Minimum
(A)
Maximum
(A)
GEN8-600 000.00 600.00
GEN10-500 000.00
500.00
GEN16-310 000.00
310.00
GEN20-250 00.00
250.00
GEN30-170 00.00
170.00
GEN40-125 00.00
125.00
GEN60-85 00.000
85.00
GEN80-65 00.000
65.00
GEN100-50 00.000
50.00
GEN150-34 00.000
34.00
GEN300-17 0.000
17.00
GEN600-8.5 0.000
8.500
NOTE:
The power supply can accept values higher 5% than the table values, however it is not recommended to
program the power supply over the rated values.
Model
Rated output Voltage (V)
Minimum
(V)
Maximum
(V)
8
10
16
20
30
40
60
80
100
150
300
600
0.000
00.000
00.000
00.000
00.000
00.000
00.000
00.00
00.000
000.00
000.00
000.00
8.000
10.000
16.000
20.000
30.000
40.000
60.000
80.00
100.00
150.00
300.00
600.00