7.
Run SAM-BA by executing the following script:
./sam-ba
The SAM-BA dialog window displays.
8.
Select the appropriate connection and board (
Figure 4
).
Figure 4: SAM-BA dialog window with connection and board selected
Connection:
/dev/ttyACM0
Board:
at91sam9x25-ek
9.
Click Connect.
10.
In the main SAM-BA window, select the NAND_Flash tab.
11.
Execute the following script:
Enable NAND Flash
12.
Verify that PMECC is enabled and set up correctly by doing the following:
a.
Execute the following script:
pmecc configuration
b.
Ensure that Ecc offset is set to 36 (
Figure 5
).
Figure 5: ECC configuration window
13.
Execute the following scripts:
Erase All