Laing Innotech LTC Series Installation And Operating Instruction Download Page 47

Instruction LTC 11           Laing Innotech GmbH + Co. KG Althuette Germany          

- 47 - 

controller to avoid e.g. 
collision with window 
board  

P8 

 

Sensitivity level for the 
collision detection 

For the current based, 
as well as the 
GyroSense based 
collision detection in this 
menu item the sensitivity 
can be adjusted. Also, 
the collision detection 
can be deactivated 

P9 

Initiate reference mode 

If the table gets out of 
level or the height is not 
indicated right, a 
reference run can be 
initiated in this menu 
item 

P10 

Change from metric to 
imperial units 

In this menu item the 
indicated units can be 
changed from metric to 
imperial 

P11 

Enter info menu 

This menu item leads to 
the information menu 

P12 

Enter service menu 

This menu item leads to 
the service menu 

P13 

Enter BLE menu 

This menu item leads to 
the BLE menu 

P14 

Enter Reset menu 

This menu item leads to 
the Reset menu 

Service Menu 

P30 

Reset user settings 

All user settings will be 
reset to the factory 
settings 

Summary of Contents for LTC Series

Page 1: ...Installation and operating instruction LTC Series...

Page 2: ...se 8 Controller with OptoSense 9 Options 9 Delivery contents 9 Installation of the controllers 10 Controllers without OptoSense 10 Controller with OptoSense 10 Controller with GyroSense 11 Installatio...

Page 3: ...sensitivity of the collision detection by LM control panels 26 Initiate a reference run by LM 26 Stroke limit adjustment by LM control panels 26 Adjust upper and lower stroke limit 26 Delete stroke li...

Page 4: ...2 Controllers by the control panel 39 Synchronization of up to 6 controllers 39 Controller connection 40 One Group Mode 40 HUB Normal Mode 40 Startup 41 BLE Option 41 WiFi Option 42 Remote service th...

Page 5: ...y can be ensured Therefore such use is not permitted and warranty will be voided if used in applications outside the table height adjustment area Whom is this document prepared for This document is an...

Page 6: ...table top Danger of collision The table must be placed in a way that it can operate without colliding with any objects like drawers or window sills Danger of injury by squeezing The table must be plac...

Page 7: ...384 Max output power 300 W 380 W 380 W Input Voltage 230 V 50 60 Hz 230 V 50 60 Hz 230 V 50 60 Hz Input current 1 5 A 2 0 A 2 0 A Frequency 50 60 Hz 50 60 Hz 50 60 Hz Output voltage 24 V 24 V 24 V Out...

Page 8: ...Laing Innotech GmbH Co KG Althuette Germany Instruction LTC 11 8 Dimensions Controller without OptoSense...

Page 9: ...app This also is required for the wireless control panel OptoSense option the controller will be supplied with the OptoSense sensor and a connector inside the controller for the OptoSense sensor This...

Page 10: ...it is important that the fixing points at the endcap of the controller not be deformed The controller can also be mounted on the cross bar in this case the mounting can be done by M4 metric screws wit...

Page 11: ...edge of the transparent cover of the sensor reaches the table top the force must be increased up to about 200N to insert the cover into the hole The cover must be pressed in until the rim of the cover...

Page 12: ...rol panel will only be pressed on the fringe or insert it by pressing with a flat tool covering the whole area of the control panel on the control panel The cable must be attached to the bottom of the...

Page 13: ...required pocket for the oval control panels to be machined in the table top Note sizes in mm Electrical connection The picture shows the output connection side of the controller 1 Motor 1 2 Motor 2 3...

Page 14: ...Pin assignment for motors below Nominal voltage 24 V Maximum current 8 A Number of hall sensors 90 2 Hall sensor supply voltage 5 V Maximum current hall sensors 50 mA Pin assignment controller Pin ass...

Page 15: ...n the order shown on the controller cover Connection of the control panels and other control options Control panels with cable The control panels with cable must be plugged into the connector 5 of the...

Page 16: ...control panels with height indication and without height indication Where a controller or control panel with height indication is connected a control panel without height indication can be added by u...

Page 17: ...LED in the controller goes off so wait about 20 to 30 seconds and only then plug it back in While the controller is ready for pairing press the keyboard UP and Down keys on the control panel simultane...

Page 18: ...l move to memory 1 position 2 Key Table will move to memory 2 position Battery change Once the controller will not react any more to the control panel the battery in the control panel has to be change...

Page 19: ...n normally the lowest point or the position of a limit switch and further until the table elevates to the lowest programmed position this may be about 25mm or 1 higher than the lowest position After t...

Page 20: ...le and the environment of the table can cause such injuries This is why no liability can be accepted for personal injury or any other damage It is the user s sole responsibility to make sure that pers...

Page 21: ...al height will be entered as travel and the drives will move downwards by the defined top margin This process will be repeated with every reference run Throughout the setting of the margins the distan...

Page 22: ...de as described below in the Menu Handling section The controller can only used to protect equipment it is not suitable to protect humans The picture shows the connection of a ribbon switch or sensing...

Page 23: ...below in the Menu handling section When the automatic motor recognition is activated in the controller it is recommended to set the number of motors to 1 when the controller is delivered to the custo...

Page 24: ...l height of the table top in centimeters or Inches depending on the configuration Configuration of the controller though the LM control panels control panels without height indication Store memory pos...

Page 25: ...ill move after the new limits have been adjusted This minimum distance is defined in the parameter set entered into the controller Saving a new upper or lower limit is not possible if the minimum dist...

Page 26: ...s four sounds the collision detection will be set to low Initiate a reference run by LM Should the table for whatever reason show the wrong height or one leg be higher than the other a reference run m...

Page 27: ...the controller Saving a new upper or lower limit is not possible if the minimum distance is not maintained In this case when pushing the appropriate arrow key to save the new limit the following short...

Page 28: ...reached or if one key press is sufficient Press the up arrow key 4 times quickly one after another Reaching the program mode will be confirmed by a sound The display will now show P01 Press the up or...

Page 29: ...the selected limit The successful storage of the user position will be confirmed by the sound shown The top and lower positions must keep a minimum distance so that the table can still move after the...

Page 30: ...ted o 2 Default setting highest sensitivity o 3 Medium sensitivity o 4 Lowest sensitivity Press the memory one key shortly to confirm the selection Initiate a reference run by the LD control panels Sh...

Page 31: ...Press the memory one key shortly to enter the menu The display now will show P50 Press the up or down arrow key to select the desired menu item Once the desired menu item is reached press the memory...

Page 32: ...mits will reach into the user height limit range As the controller will be supplied with set limits changes can only be made when the present value is deleted as described below after that a new limit...

Page 33: ...ow will show P30 Press the up or down arrow key until the display shows o P31 for the deletion of the upper stroke limit the table must be at the highest position o P32 for the deletion of the lower s...

Page 34: ...show the actually set value By pressing the up or down arrow key the desired setting can be selected o 0 the display will show the first decimal o 1 the display will show only 0 or 5 as decimal o 2 th...

Page 35: ...ss control panel to the controller it must be paired To do this the controller must be put into pairing mode This can be done in two ways 1 After the controller is connected to the mains it will be in...

Page 36: ...In this mode only the smart phone what activated the private mode can communicate with the controller By this menu item the private mode can be reset after that the controller is accessible through al...

Page 37: ...alue will be saved Reset Safety Adapter The controller can be configured to activate the safety input function automatically when the safety adapter is plugged into the Motor 1 connection Thereafter t...

Page 38: ...ntil the hand is moved outside the sensing area of the OptoSense Sensor If after activation the hand is moved down for only a small distance the table will start to move downwards until the hand is mo...

Page 39: ...Y Adapter will now configure the Hub Mode in the controllers Now all drives connected to the two controllers will be synchronized If only one controller is connected to the Sync Y Adapter no operation...

Page 40: ...an be connected to a different port but the total number of controllers must correspond to the highest number of controllers what have been connected to the HUB If a smaller number is connected the HU...

Page 41: ...r groups the control panel is assigned to will start moving This is true also for the OptoSense BLE or WiFi module in one of the connected controllers as long as they are assigned to a group If more t...

Page 42: ...the controller and all information inside the controller can be initiated and accessed through WiFi The controller identifies itself in the network by its serial number or by the name assigned to it...

Page 43: ...the bus connector of the controller and plug it into one of the two RJ12 connectors of the Cloud interface Plug the one end of the bus cable supplied with the Cloud Interface into the bus connector o...

Page 44: ...ce mode Press up or down button to perform a reference run Keep button pressed until the reference run is finished Short and long blinks The LED shows a sequence of long and short signals This indicat...

Page 45: ...wer limit Users can set individual upper and lower limits for their controller to avoid e g collision with a window board above or drawer container below the table PM3 three sounds Adjust sensitivity...

Page 46: ...mory position 2 The memory position two for the control panel memory key two can be stored P3 Store memory position 3 The memory position three for the control panel memory key three can be stored P4...

Page 47: ...e table gets out of level or the height is not indicated right a reference run can be initiated in this menu item P10 Change from metric to imperial units In this menu item the indicated units can be...

Page 48: ...display will indicate P34 Display precision Set if the indicated value is rounded to 0 1 0 5 or 0 0 BLE Menu P40 Activate BLE Activate or deactivate the BLE P41 Reset controller name Controller name w...

Page 49: ...52 OptoSense enabled disabled P53 BLE enabled disabled P54 WiFi enabled disabled P55 Charge state battery Shows the actual charge state of the battery P56 Battery temperature Shows the actual battery...

Page 50: ...ntroller and the control panel Check the electrical connection Reference mode The controller entered reference mode a reference run must be performed F1 LED blinking long short short short EEPROM init...

Page 51: ...inking short short long short EEPROM inconsistency error Reset error by pressing any key If the Error remains restart system by unplugging the power cable of the controller and plugging it in again af...

Page 52: ...LED blinking long short short long Maximum allowed energy amount I2t entered into the motors Wait for some time to allow the motors to cool back The I2t decrease mechanism allows partial usage of the...

Page 53: ...F13 LED blinking long short long long Maximum temperature level of the motor three and four drive reached Wait for some time to allow the controller to cool back Reset error by pressing any key F14 LE...

Page 54: ...er was configured for Check if all motors are properly connected to the controller Reset error by pressing any key F17 LED blinking long short short short long Controller overloaded Reset error by pre...

Page 55: ...tion Acknowledgement signal The sound acknowledges a selection Fail signal The sound indicates that a selection could not be made as intended Deletion confirmation The sound indicates that a value has...

Page 56: ...ions The CE sign is based on the compliance to the following standards EN 60335 1 2012 EN 61000 6 3 2007 EN 61000 6 2 2005 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 62233 2008 ISO 13849 2...

Page 57: ...Instruction LTC 11 Laing Innotech GmbH Co KG Althuette Germany 57...

Reviews: