Laing Innotech GmbH + Co. KG Althuette Germany Instruction LTC 11
- 12 -
Installation control panels
Rectangular control panels
The square control panels will be mounted from the bottom to the edge of the
table top in a way that the keys will be easily accessible. The cable must be
attached to bottom of the table top in a way that it does not put tension on the
control panel or the controller but also does not hang loose.
Round control panels
For the installation of the round control panels a 2-3/8” through hole has to be
drilled into the table top. Then the cable will be put through the hole from the top,
then the control panel will be pressed from the top into the hole.
Make sure the
control panel will only be pressed on the fringe or insert it by pressing with
a flat tool, covering the whole area of the control panel,
on the control
panel.
The cable must be attached to the bottom of the table top in a way that it
does not put tension on the control panel or the controller but also does not hang
loose.
Oval control panels
For the installation of the oval control panels an appropriate pocket and a ½” hole
have to be machined into the table top. The cable will be put through the hole
from the top, then the control panel will be pressed from the top into the pocket.
While inserting the control panel make sure the control panel will not be
pressed too hard, if required the size of the pocket has to be adjusted.
The
cable must be attached to the bottom of the table top in a way that it does not put
tension on the control panel or the controller but also does not hang loose.