Fitting the depth
gauge.
Fit the depth gauge to
the two brackets on the
machine with the
screws provided.
Setting of the depth
gauge is covered later
in the manual.
Depth gauge
brackets
Depth
gauge
Connecting the electrical supply.
Note.
A qualified electrician must carry out the installation
.
Ensure that the main supply corresponds with that of the machine
[
Single phase
220 V].
It is recommended that you use a 30-amp main breaker.
If you need a longer cable than that supplied on the machine, you can connect a
new cable into the internal power termination.
Note. The machine is not normally supplied with an electrical plug, as the
type of plug will be dependent on the installation.
Connecting the dust collection.
Connect a 4 inch flexible hose between the dust collection hood and your dust
collector.
Once fitted pull on the hose to ensure that the connection is tight. You do not
want it to come off during production.
Note.
You will need a dust collection system with a minimum of 1000 cubic
feet per minute capacity. The stronger the dust collection the better, as the
machine is capable of producing a lot of waste.
1