Explanation of the operating elements
Operation
16
EN 1108 6.6702.171-03 Printed in
Germany Subject
to change without notice
Technical data
Supply voltage complying with
DIN IEC 60 038
230 V AC
±
10%
Power consumption
Max. 5 VA
Switching capacity of the relays 250 V AC 2(2) A
Switching capacity Triac (T3/T4) 250V AC 1,2(1,2) A
Maximum current on terminal
L1'
6.3 A
Type of protection complying
with DIN EN 60529
IP 40
Protection class complying with
DIN EN 60730
Totally insulated
Permitted ambient temperature
during operation
0 to 50°C
Permitted ambient temperature
for storage
-20 to 60°C
Permissible humidity non
condensing
%95 r.H.
Sensor resistances
Tolerance in ohms
Temperature tolerance
Tolerance in ohms
Temperature tolerance
NTC 5 k
Ω
(AF,KF,SPF,VF)
+/- 1% at 25°C
+/- 0.2K at 25°C
PTC 1010
Ω
(AFS,KFS,SPFS,VFAS)
+/- 1% at 25°C
+/- 1.3K at 25°C
Malfunctions due to improper operation or settings
are not covered by the warranty.