4  Logger. 

Logger is designed to register history of recorder’s operation and emergencies to the non-

volatile memory. 

 
In addition, logger contains  manufacturing  data (recorder identification number and 

firmware number) 

 

  

Logger stores from 32 to 48 latest events, as well as their time and date. 

 

If the logger is turned on (see. 2.6 (i)) and voice recorder is switched off (except 

emergency reset) logger is recorded to micro SD into the file INF_REG.TXT. 

 

It is not recommended to use the logger continuously

 

since this reduces nonvolatile 

memory resource of the voice recorder (it only affects work of the logger itself). 
 

 Brief description of the recorded events and the logger structure is given in Table 5. 

 
Table 5. Description of logger tags and events.

 

 

Shorthand 

Description 

DEVICE_NUMBER 

Identification number of the voice recorder 

POWER_RESET 

Reset by power failure 

PIN_76_RESET 

Processor hardware reset 

PMMSWBOR 

For official purposes 

WAKE_UP_FROM_LPX.5 

For official purposes 

SECURITY_VIOLATION 

For official purposes 

SVSL 

For official purposes 

SVSH 

For official purposes 

SVML_OVP 

For official purposes 

SVMH_OVP 

For official purposes 

PMMSWPOR 

For official purposes 

WATCH_DOG_TIME_OUT 

Looping / stop of  the  processor’s program due to    not 
serviceability of  card or software failure 

WDT_PSWRD_VIOLATION 

For official purposes 

FLASH_PSWRD_VIOL 

For official purposes 

PLL_UNLOCK 

For official purposes 

PERF_AREA_FETCH 

For official purposes 

PMM_PSWRD_RESET 

Forced software reset (occurs when overwriting voice 
recorder microprocessor program). Is called forcibly. 

LOW_VOLTAGE_TURN_OFF 

Low Battery - The recorder is turned off 

BUTTON_TURN_OFF 

Voice Recorder is turned off by pressing 

BUTTON_TURN_ON 

Turning the voice recorder on by pressing 

SD_MEMORY_IS_OVER 

No free space on the microSD -  the  voice  recorder  is 
switched off 

ALARM_TURN_OFF  

Voice recorder is turned off by timer 

ALARM_TURN_ON 

Voice recorder is turned on by  timer 

SD_READ_TIMEOUT 

Micro SD does not respond to a command to read data 

 

Page16 

Version of 14.05.2018 

Summary of Contents for SOROKA-16E

Page 1: ...Laboratory2 LTD SOROKA 16E DIGITAL VOICE RECORDER OPERATIONAL MANUAL Page1 Version of 14 05 2018...

Page 2: ...ations 8 2 2 Preparation of the voice recorder for usage 8 2 3 Rechargeable battery charging 8 2 4 Setting voice recorder parameters 9 2 5 Usage of the voice recorder 9 2 6 Creating a configuration fi...

Page 3: ...pabilities of the voice re corder SOROKA 16E Fig 1 Delivery set of voice recorder Soroka 16E Table 1 List of items supplied Name Quantity Option 16 1E 16 2E 1 Voice Recorder Soroka 16E 1 2 Micro SDHC...

Page 4: ...te 8 kHz 3 Hz 3 384 kHz 16 kHz 3 Hz 6 768 kHz 24 kHz 3 Hz 10 152 kHz 32 kHz 3 Hz 13 536 kHz 12 Duration of work when the resolution is 16 bit with u law compression Sample rate Typical operating time...

Page 5: ...dB 24 Automatic sound level adjusting Yes only 16 bit only with resolution and compres sion u law from 12 dB to 18 dB in 6 dB 25 Logger Yes 26 System of tags of records in files tags at the beginning...

Page 6: ...ssible only by pressing a button b Mono recording mode after the brief pressing of control button 1 If the battery voltage is normal the indicator repeatedly blinks green internal microphone orange ex...

Page 7: ...f the rechargeable battery Indicator Charge lights green b Charge of the rechargeable battery indicator Charge lights red 1 4 Design and operation of the voice recorder The appearance of the voice rec...

Page 8: ...oice re corder Before starting to use the voice recorder it is necessary to carry out an external inspec tion for mechanical damage On the surface there should be no cracks chips dents Metal parts sho...

Page 9: ...ing To display the voice recorder current status briefly press the control button The cur rent state is determined according to the indications on the table 3 To switch the recorder off press the cont...

Page 10: ...voice operated switch by setting of value in the Sensitivity of VOX window The higher the chosen sen sitivity the by more quiet sounds are recognized by recorder The recommended sensitivity value is a...

Page 11: ...antly increase record duration and by two tree times decrease memory consumption on the microSD card in comparison with the record modes in a format 16 20 bits without compression i Switching on off l...

Page 12: ...nth and activation time as well as record duration after which voice recorder will switch off and expect activation of the following alarm clock Alarm clocks work in strict sequence from the first to...

Page 13: ...the tab Verifying of file integrity there are the following controls a Open the file Click Open File and select the desired directory and file After se lecting of the desired file the program will pe...

Page 14: ...available in the labels file The report contains information about the number of tags in file to be scanned their names and their corresponding samples This file has the same name as the file which is...

Page 15: ...g The labels in the recorded files are placed in the following cases 1 At the beginning and at the end of each file 2 When you press the control button of voice recorder for the purpose of marking the...

Page 16: ...PMMSWBOR For official purposes WAKE_UP_FROM_LPX 5 For official purposes SECURITY_VIOLATION For official purposes SVSL For official purposes SVSH For official purposes SVML_OVP For official purposes S...

Page 17: ...ll UNDEFINED_ERROR Unspecified error or reset DICT_SOFTWARE_NUMBER Number of internal software recorder software 5 Current repair of the voice recorder 5 1 General instructions If any defect of the vo...

Page 18: ...s with air temperature over 25 C 7 Manufacturer s warranty 7 1 The manufacturer guarantees the accordance of the voice recorders to the technical requirements providing that the customer obeys instruc...