BA_008_2019-11_10.01  Pressure gauges 

Page 4/5 

Operation 

During operation, take care that the device remains within its intended pressure and tem-
perature ranges. No other monitoring is necessary. 

  

The  permissible  ambient  and  media  temperature  depends  on  the  type  of  device  and  its 
design. This information can be found in the relevant data sheet. 

  

4.1  Zero-point correction 

Small  measuring  errors  or  deviations 
caused by difference in level between pres-
sure  gauge  and  point  of  measurement  can 
be  corrected  on  measuring  devices  with 
micro  control  position  pointers.  To  do  so 
turn  the adjusting  screw  on  the  pointer  hub 
(see figure 4).  

Similarly,  a  displacement  of  the  zero  point 
caused  by  use  and  long  service  life  can  be 
corrected if necessary. 

You can find further information about zero-
adjustment  of  pressure  gauge  with  micro 
adjustment pointer in the document TA_029 
on www.labom.com.  

 

Figure 4: Zero-point correction 

  

4.2  Devices with Diaphragm Seal 

Remove the protective cap or protective wrapping from the diaphragm only just before in-
stallation to prevent contamination or damage. 

The  diaphragm  must  not  be  touched.  Do  not  place  the  device  on  its  diaphragm.  Even 
small scratches or deformations may negatively influence the zero point or other charac-
teristics of the device. 

Pressure transmitter and diaphragm seal are a closed system that must not be separated. 

You  can  find  further  information  about  diaphragm  seals  in  the  document  TA_031  on 
www.labom.com.  

  

4.3  Maintenance / Service 

When  properly  installed  in  accordance  with  applicable  specifications,  this  device  is 
maintenance-free. However, we recommend an annual recalibration of the device. 

  

In  the event  of  any  damage or  defect  the  customer  cannot  replace  or  repair  any  compo-
nents or assemblies. 

  