LOKASET R

    |    Installation and Operation Instructions     |    D18067Ae

7. Lokaset R – Technical Specifi cations

Central Unit

Type/model

Manufacturer  

Supply voltage

Operation method

Relay output

Dimensions: hxwxd

Installation and  

operation class

Operation

Approvals

Lokaset R Receiver

Labkotec Oy, Myllyhaantie 6,

33960 Pirkkala, Finland

230 VAC, 50/60 Hz, 1 VA

Wireless receiver, 433 MHz

De-energised on alarm,  potential-free 

switching contacts (μ).  Max. connection 

values: 250 V / 4 A / 100 VA

35 x 130 x 80 mm

Class II, Indoor use only

Green, blue and red indicator light, buzzer

R&TTE approval, 

CE Marking

Transmitter

Type/model

Manufacturer 

 

Supply voltage

Operation method

Dimensions: h x Ø

Operating radius

Installation and   

operation class

Protection class

Approvals

Lokaset R Transmitter

Labkotec Oy, Myllyhaantie 6,

33960 Pirkkala, Finland

3 V battery, CR 123A

Wireless transmitter, 433 MHz

75 x 95 mm

150 m, max. transmission range 650 m

Class III, indoor and outdoor use,                 

ambient temperature -30 … +60°C

IP 67

R&TTE approval,  

CE Marking

Probe

Type/model

Operation method

SET/LV

Conductivity-operated

Summary of Contents for LOKASET R

Page 1: ...LOKASET R Installation and Operation Instructions D18067Ae WIRELESS TANK FULL ALARM...

Page 2: ...LOKASET R Installation and Operation Instructions D18067Ae 2...

Page 3: ...LOKASET R Installation and Operation Instructions D18067Ae Contents 1 Introduction 4 2 Operation 5 3 Installation 6 4 Operating Mode 8 5 Service and Repairs 9 6 Alarms 10 7 Technical Specifications 1...

Page 4: ...he central unit is used for controlling and monitoring device operation The enclosed transmitter transmits the alarm signal wirelessly from the probe to the central unit Lokaset R can be installed in...

Page 5: ...th a buzzer sound and an alarm indicator light 2 The buzzer is silenced by the alarm reset button 3 The alarm mode can be deactivated by emptying the tank The probe should be installed in the tank at...

Page 6: ...nd the transmitter should be tested during installation in order to ensure that the radio signal can travel freely Activate the transmitter test mode see Service instructions p 9 Immerse the measuring...

Page 7: ...ng O ring 8 69 5 x 3 0 mm NBR70 is seated properly in the groove Close the protective cover 9 with the supplied stainless steel screws 10 2 pcs 3 x 16 mm Note Proper seating of the O ring and tightnes...

Page 8: ...Lokaset R central unit has three indicator lights and one button The green light POWER is the power indicator the blue light SIGNAL the wireless transmission indicator and the red light ALARM the alar...

Page 9: ...probe is during tank emptying The probe may be cleaned using running water Operation of the Lokaset R device can be checked in conjunc tion with maintenance by activating the transmitter test mode Act...

Page 10: ...being paired Press the function button p 9 on the Lokaset R transmitter The green light POWER and red light ALARM are on and the blue light SIGNAL flashes Complete the process by pressing the central...

Page 11: ...connection values 250 V 4 A 100 VA 35 x 130 x 80 mm Class II Indoor use only Green blue and red indicator light buzzer R TTE approval CE Marking Transmitter Type model Manufacturer Supply voltage Oper...

Page 12: ...Labkotec Oy Myllyhaantie 6 33960 Pirkkala Finland Tel 358 29 006260 exchange Fax 358 29 0061260 info labkotec fi www labkotec fi We reserve the right to changes 2009 Labkotec Oy...

Reviews: