4.
Installation
4.1. Installing the control unit
The idOil control unit is wall mounted. Installation holes are located at the bottom part of the
box under the mounting holes for the cover.
The cover of the box must be tightened so that the edge touches the bottom part. This
ensures that the reset and test button functions well and the enclosure is tight.
The control unit must be installed in a safe (non-Ex) space.
Read Section General safety instructions before installation.
1 Cable glands M16 grey, 3 pcs
2 Cable glands M16 blue, 2 pcs
3 Fastening holes Ø4.5 mm, 4
pcs
Installation dimensions 160 x
110 mm
Figure 6. Installing the idOil control unit
4.2. Sensor installation
idOil sensors can be installed in zone 0 explosive atmospheres. Do not
remove the sensor markings from the cables or sensor frames.
Read Section General safety instructions before installation.
Check the correct installation depth of the sensor in the instructions of the
separator in question.
For example, sensors can be installed suspended from their cable (see
next figure). Leave a sufficient length of the sensor or extension cable
coiled inside the service well, so that you can easily lift the sensor out for
inspection and cleaning.
Installation and Operating Instructions | idOil-20
11/34
DOC001600-EN-5
Summary of Contents for idOil-20
Page 29: ...Installation and Operating Instructions idOil 20 29 34 DOC001600 EN 5...
Page 30: ...Installation and Operating Instructions idOil 20 30 34 DOC001600 EN 5...
Page 32: ...Installation and Operating Instructions idOil 20 32 34 DOC001600 EN 5...
Page 33: ...Installation and Operating Instructions idOil 20 33 34 DOC001600 EN 5...
Page 34: ...Installation and Operating Instructions idOil 20 34 34 DOC001600 EN 5...