SPECIFICATIONS:

 

 
Max. Label Roll Weight:

  

6Kg (13.2Lb)  

Max. Label Roll Size:

   

330mm (13") diameter  

Power Supply:  

 

Input: 220-240VAC – 50-60Hz.   

 

    Output: 

24VDC 

– 

4.17A. 

Speed: 

   

Min. 65cm/sec with 76mm take-up roll diameter. 

 

 

 
SET-UP:

 

 

1.  Plug the Power Supply Output Cable to the Power Jack on the Rear Panel of 

the RRC-330. Plug the Power Supply into a suitable AC Power Mains Outlet. 
Place the Power Switch on the rear of the RRC-330 to the “ON / 1” position. 
Observe that numbers are displayed on the Counter. 

See the separate User Manual for the Counter Modules itself for other 
operations. 

2.  The Counter is pre-programmed as a Preset Count-Up Counter. If you want 

to use the preset function, introduce the number of labels with the blue push 
button on the counter. If you do not want to use preset, set the value to “0”. 

3. 

When the preset number of labels is reached, the RRC-330 will stop. 
Pressing “R” on the counter will reset the count and restart the RRC-330

 

 

 

 

 

OPERATION:

 

 
1.  Place the “STOP / RUN” Switch in the STOP Position. 

2.  Place your Roll of Labels on the Roll Holder at the left of the RRC-330. The 

Take-Up Spindle on the right rotates in a counter-clockwise direction. Note 
that your rewind can be “Wind-In” or “Wind-Out” according to which way you 
place the Label Roll on the Roll Holder, right-side-up or upside-down.  

3.  The 2 plastic rings on the paper guides need to be used only if the unwind 

roll is unevenly wound to begin with. Setting the rings at the proper height will 
correct the unevenness of the roll on the rewind side.  

4.  The machine will stop when out of paper. To re-start, load paper, and set the 

Stop/Run Switch to STOP. Re-set the counter if necessary. Start by 
switching to “RUN”. 

5.  Place an empty label Core (not included) over the Take-Up Spindle and 

secure the Label Web using a piece of tape. 

6.  Enter the desired Label Count via the Push Buttons on the Counter. If you do 

not use preset, set the value to “0”. 

 

IMPORTANT!

 

 
It is recommended to use the machine at its maximum speed.  
Keep unwind plate clean of particles and glue. 
 

 

LEFT SIDE CONTROL PANEL: 
 

 

RESET:

 The new left-side control panel has 

three items. The toggle switch (reset) is a 
momentary closing switch, that has the same 
function as the reset button on the counter, 
but is more convenient for the operator. 

ADJUST

: Potentiometer.  

TEST

: Green LED 

 

 
ADJUSTING THE LABEL DETECTOR PHOTOCELL:

 

 

The label detector photocell has been adjusted at the factory (potentiometer fully 
CCW) and requires no adjustment for a large variety of labels. However, some 
specific labels (very transparent or relatively opaque backing paper) might 
require adjustment of the photocell. 
 
Load a roll of labels on the machine, and position the backing paper in front of 
the photocell. Make sure that the labels are tensioned when doing the test. The 
LED should light on. If not, rotate the potentiometer till LED goes on “green”. 
Now put a label in front of the photocell, the LED should turn off. 
 

  

WARNING

!

 

This Product is for indoor use only.   

Not for use in wet locations. 