COUNTER USE

1. Place the C-100-US Label Counter so that it is perpendicular to the

label web.

2. Observe the Web Path Label on the Counter Chassis.
3. To count labels, feed the label web under the rotating metal Rollers

and  through  the  sensor.  The  labels  must  pass  through  the  Label

Sensor Gap between the rotating metal Rollers.

4. Adjust the position of the Rings on the two rotating metal rollers to the

width of your Label Web and tighten the Screws.

5. Affix the leading edge of the label web to the Label Rewind Core on

the Label Rewinder.

6. The  Rewinder  being  used  as  the  Unwinder  for  the  Supply  Roll  of

Labels can be placed in the OFF Position or in the “reverse direction”

with a very small amount of back-tension as desired.

SELF-TEACHING ULTRASONIC SENSOR

To begin counting labels, once the labels have been threaded through

the  Sensor  press  and  hold  the  “T”  button  until  the  green  and  yellow

LED’s  flash  simultaneously.  Release  the  “T”  button  and  advance  the

label stock through the sensor until the  LED’s stop flashing and  only

the green LED is shining. Manually rotate the Supply Roll until the first
label you want to count is properly positioned. Reset the Counter to 0

and start the unit.

NOTE:

You  can  slide  the  Sensor  forward  and  back  on  the

mounting  bracket  to  adjust  for  different  label  sizes  by  loosening  the

knob that holds it in place. Once the sensor is in the optimum position,

retighten the knob to secure the sensor in place.

WARNING

This product is for indoor use only.

Not for use in wet locations.

PC-1 PRESET COUNTER SET-UP

Plug  the  Control  Cable  (with  3.5mm  plugs  at  each  end)  between  the

Output  Jack  on  the  bottom  of  the  Counter  Display  Module  and  the

“EXTERNAL HALT CONTROL” jack on the CAT-3 Label Rewinder.

The  Counter  is  pre-programmed  as  a  Preset  Count-Up  Counter.    Press

each of the 6-digits for the count desired. This is the number of labels

you wish to pass through the Label Sensor before the Counter issues

a “HALT” command to the CAT-3 Label Rewinder.

Pull  a short strip of labels  back and forth through the Label  Sensor Gap

and  observe  the  count  on  the  Counter  increasing.  When  the  preset

number  of  labels  is  reached,  the  PC-1  Counter  will  issue  a  Halt

Command for the CAT-3 Label Rewinder to stop.  Pressing “RESET”

will reset the count.

See  the  included  detailed  manual  for  the  Pre-set  Counter  itself  for  other

Counter options.

PRESET COUNTER DISPLAY MODULE

1. The Counter is pre-programmed as a Preset Count-Up Counter.
2. Pull  a  short  strip  of  labels  back  and  forth  through  the  Label  Sensor

Gap and observe the count on the Counter increasing.

3. Press each of the 6-digits for the Pre-set Count desired. When the pre-

set number of Labels has  passed through the Label  Sensor Counter

issues a “HALT” command to both CAT-3 Rewinders and the System

will stop. If you don’t want to use the Pre-set Feature, set the Preset

Number to a very high value.

4. Pressing the white “RESET” Button on the top of the Counter will reset

the count.

Please see the CAT-3 Rewinder User Manual for more information.

MAINTENANCE

The Ultrasonic Label Counter requires no maintenance.