If the led is permanently on or flashing, it means that there is no
communication between the selector and the control unit..
In this case, check the electrical connection
Make sure that the LOGIC TAST module is installed.
Input status indication..
When on, the led indicates that the input is engaged.
Work program selection: press the SET button to change the type of
program.
Clockwise, traffic in 2 directions, exit only, entrance only, doors always
open, night lock
Press the key (green led on) to activate the door free function.
The motor is not powered and the door can be moved by hand.
Press the key (green led on) to inhibit the stepping function activated
by dip-switch DIP 1 of S2.
9) DIGITAL SELECTOR
The package with digital selector also contains the LOGIC TAST electronic board, which is the interface module required for
exchanging data between digital selector and the electronic control unit.
The LOGIC TAST board must be fitted into connector J8 of the LGN part of the electronic control unit (see fig.2 in sect. 2).
A 4-pin terminal board in the package is used for the electrical connection between digital selector and terminal board M4 of
the PWN part of the electronic control unit.
F1
FREE FUNCTIONS
(the work program can be changed by pressing SET)
FUNCTIONS BLOCKED
LOGIC TAST