MAINTENANCE PROGRAM
Maintenance program for swing door NEPTIS/LE:
Each 6 month:
! Attention- Before work on the operator cut main power line.
-
Check that all securing screws are well tightened.
-
Clean and lubricate moving and sliding components.
-
Lubricate closing spring if present.
-
Check wiring connections.
-
Check that arm connection screw are well tightened.
-
Check that door leaf are stable and the movement is steady, without friction from full
open to full close position.
-
Check the condition of the hinges and lubricate it.
-
Check that speeds, timing, and safety functions are well adjust.
-
Check that safety and activation sensor are properly functioning.
!Attention-Any part that appear damaged or worn must be changed.
For spare parts see the spare part list.