Operation test
1. If the automated equipment is a single leaf door with rightward opening, set the dip 5 of S1 ON, if the automated
equipment is double leaf or single leaf door with leftward opening, set the dip 5 of S1 OFF.
2. If the automated equipment is an EVOLUS 90, set the dip 9 of S2 OFF; if it is an EVOLUS 150 set the dip 9 of S2
ON.
3. If the electric lock model FAIL-SAFE is present, set the dip 9 of S1 ON; if the electric lock model FAIL-SECURE is
present, set the 9 of S1 OFF.
4. Supply power to the control unit with 230Vac, that will emit an initial beep and a short series of close beeps.
5. Press and hold the PS2 SET-UP button as long as the control unit buzzer emits the fast beeps, then release it
when the control unit emits the 4 final beeps preceding motor starting.
6. The electric lock, if any, will free the hooking bracket on the carriage and the motor will run slowly in the closing
direction until when the carriages with belt coupling shall arrive at the end of stroke, afterwards, the motor will run
slowly in the opening direction.
After a small distance of opening stroke, turn off the control unit.
Close the container of the control unit with the cover by
screwing it with the two screws provided.
Insert the articulation of the link provided with pin under
the covering guard.
·
Then, this articulation shall be coupled with the link which
had been fastened to the transom, in order to
guarantee the support of the guard when the automated
equipment is open.