background image

Chapter 4: Features and Safety Precautions 

 

Product Service 1-800-522-7658 

11 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.

 

Ergonomic Slope and Front 

of 20

° 

provides maximum visibility, and 

comfort, reduces glare, thereby minimizing operator fatigue. 

2.

 

Internal Depth of 23" and interior height of 22" 

provides necessary 

depth and height to support procedures and other auxiliary equipment 
without extending outside the non-ventilated enclosure. 

3.

 

Flush Sash 

has a wiping seal and features a spring-loaded latch for loading 

auxiliary equipment.  The sash pivots down for normal operation. 

4.

 

Electrical Pass-Through Iris 

allows electrical cords and data cords to pass 

through the back of enclosure.  The unit ships with solid plugs and the iris 
plugs are included with the User’s Manual for your convenience. 

5.

 

Fluorescent Light 

provides illumination for the interior of the enclosure. 

6.

 

Ultraviolet Germicidal Light 

provides surface decontamination and 

maintains sterility inside the enclosure.  It is located above the work area. 

7.

 

Variable PCR Digital UV Light Timer (Purifier PCR Enclosure only) 

allows the operator to time the surface disinfection of the work area for 
PCR protocols.  The UV light timer has eight settings of 5, 10, 15, 30, 60, 

Figure 4-1 

Features 

9, Internal 

10, Not 

Shown 

PCR 

Summary of Contents for Purifier 3951400

Page 1: ...conco labconco com HOME PAGE www labconco com To receive important product updates complete your product registration card online at register labconco com User s Manual Purifier Non Ventilated PCR Tissue Culture Enclosures Models 3951400 3951420 3952400 3952420 Please read the User s Manual before operating the equipment ...

Page 2: ... questions that are not addressed in this manual or if you need technical assistance contact Labconco s Customer Service Department or Labconco s Product Service Department at 1 800 821 5525 or 1 816 333 8811 between the hours of 7 00 a m and 6 00 p m Central Standard Time Part 3939201 Rev A ECO J105 Warranty Labconco provides a warranty on all parts and factory workmanship The warranty includes a...

Page 3: ...Unpacking Your Enclosure 7 Installing the Enclosure on a Supporting Structure Work Surface 7 Connecting the Electrical Supply 9 Sealing the Enclosure to the Work Surface 9 CHAPTER 4 FEATURES AND SAFETY PRECAUTIONS 10 Features 10 Safety Precautions 12 CHAPTER 5 USING YOUR ENCLOSURE 13 CHAPTER 6 MAINTAINING YOUR ENCLOSURE 14 Routine Maintenance Schedule 14 UV Light Replacement 14 Fluorescent Light R...

Page 4: ...CHAPTER 8 TROUBLESHOOTING 18 APPENDIX A REPLACEMENT PARTS 19 APPENDIX B DIMENSIONS 22 APPENDIX C SPECIFICATIONS 23 DECLARATION OF CONFORMITY 24 ...

Page 5: ...NA is immersed in a solution containing the enzyme DNA polymerase unattached nucleotide bases the subunits that DNA is composed of and primers short sequences of nucleotides designed to bind with an end of the desired DNA segment Two primers are used one primer binds at one end of the desired segment on one of the two paired DNA strands and the other primer binds at the other end but on the other ...

Page 6: ... the manual and defines the typographical conventions used in the manual Chapter 2 Prerequisites explains what you need to do to prepare your site before you install the enclosure Electrical and service requirements are discussed Chapter 3 Getting Started contains the information you need to properly unpack inspect and install the enclosure Chapter 4 Features and Safety Precautions explains how th...

Page 7: ...esult in injury to the user or permanent damage to the enclosure Critical information is presented in boldface type in paragraphs that are preceded by the wrench icon A trained certifier or contractor should only perform these operations Failure to comply with the information following a wrench icon may result in injury to the user or permanent damage to your hood Important information is presente...

Page 8: ...ucture usually consists of a base cabinet and chemically resistant work surface A mobile stand or cart is allowable See Chapter 7 for accessory work surfaces stands mobile stands and cabinets Location and Air Current Requirements The Purifier Passive PCR and Purifier Tissue Culture Enclosures have been designed to reduce cross drafts and air circulation with the sash and UV sash closure panel inst...

Page 9: ...ion Electrical Requirements Standard duplex electrical receptacles should be nearby for connecting the non ventilated Purifier Passive PCR Enclosure or Purifier Tissue Culture Enclosure For your convenience the enclosures have a switched auxiliary outlet receptacle The auxiliary switched outlet is rated for either 115V 8 amps or 230V 4 amps Space Requirements The dimensions for the non ventilated ...

Page 10: ...upporting structure and work surface Connect the electrical supply Seal the enclosure to the work surface Depending upon which model you are installing you may need wrenches ratchets sockets a nut driver set a flat blade screwdriver a Phillips screwdriver and a carpenter level to complete the instructions in the chapter The enclosures weigh 100 lbs 45 kg The shipping container allows for lifting w...

Page 11: ...e by tilting it onto a hand truck Installing the Enclosure on a Supporting Structure and Work Surface When installing the enclosure onto a chemically resistant work surface or benchtop ensure that the structure can safely support the combined weight of the enclosure and any related equipment The work surface should be at least as wide and deep as the non ventilated enclosure to properly support it...

Page 12: ... front of the work surface wide flange towards you 3 Secure the work surface to the base cabinet with a structural adhesive or silicone sealant 4 Insert the supplied mounting screws in the four holes Allow a minimum of 1 8 clearance under the head of the screw for positioning the enclosure 5 Place the enclosure on the work surface and slide the rear flange and lower front bracket flanges under the...

Page 13: ...s SHOULD be performed by a licensed electrician and conform to all local codes Do not use any detachable power cord that is not adequately rated for the unit Ne pas utliser un fil électrique amovible qui n est pas du tension nominale de l appareil Sealing the Enclosure to the Work Surface When the enclosure has been set in place it may be sealed at the work surface to prevent spilled materials fro...

Page 14: ...interior and convenience outlet give ample room for media preparation and equipment used for procedures A UV light with digital timer included on the Purifier PCR Enclosure provides decontamination control after PCR protocols are conducted The Purifier Tissue Culture Enclosure may be used for techniques such as tissue staining culture growth and virus harvesting A built in UV light on the Purifier...

Page 15: ...al operation 4 Electrical Pass Through Iris allows electrical cords and data cords to pass through the back of enclosure The unit ships with solid plugs and the iris plugs are included with the User s Manual for your convenience 5 Fluorescent Light provides illumination for the interior of the enclosure 6 Ultraviolet Germicidal Light provides surface decontamination and maintains sterility inside ...

Page 16: ...icals in this enclosure 3 All acid use in this enclosure is prohibited 4 Radioisotope materials are prohibited in this enclosure 5 The use of safety goggles protective clothing gloves and any other personal protective equipment recommended by your safety officer should be used 6 The sash should remain in the down position while using the enclosure 7 Ensure the enclosure is connected to an electric...

Page 17: ...leeved lab coat and rubber gloves Use protective eyewear Wear a protective mask if appropriate Consult your Safety Officer for additional personal protective equipment recommendations Work Techniques Keep all materials inside and perform all operations inside the work area Unloading Materials and Equipment All open trays weigh vessels and containers should be covered before being removed from the ...

Page 18: ...ication Monthly or more often as required Using a cloth and glass cleaner clean the exterior surfaces of the non ventilated enclosure particularly the front to remove any accumulated dust All weekly activities Annually Replace the UV lamp Verify proper operation of the UV panel safety switch All monthly activities UV Light Replacement 1 Disconnect power 2 Locate the UV lamp inside 3 Rotate and rem...

Page 19: ...placement 1 Disconnect power 2 Locate the two Phillips machine screws on top of the light and remove Lift up the light assembly 3 Rotate and remove the old fluorescent lamp 4 Reinstall the new fluorescent lamp light and screws in reverse order 5 Switch unit on and try the new fluorescent lamp ...

Page 20: ... the addition of accessory work surfaces storage cabinets base stands and mobile stands 1 Work Surfaces An optional dished work surface is available Dished work surfaces are contoured to fit the enclosure to contain spills Epoxy is chemical resistant Catalog Description Dimensions W x D x H 3908402 Black 4 foot wide 48 x 26 66 x 1 3908405 Gray 4 foot wide 48 x 26 66 x 1 ...

Page 21: ...00 9905000 9905200 24 ADA w Self Closing Doors 9906200 9906300 18 ADA 9905100 9905300 12 ADA STANDARD BASE VACUUM PUMP Size Description Dual Doors Right Hinge Left Hinge Dual Doors Right Hinge Left Hinge 48 9900000 36 9900100 30 9900200 24 9900300 9900600 18 9900400 9900700 9907000 9907100 12 9900500 9900800 48 w Self Closing Doors 36 w Self Closing Doors 30 w Self Closing Doors 24 w Self Closing ...

Page 22: ...ly Inspect lamp installation Lamp Wiring disconnected Inspect lamp wiring Defective lamp Replace lamp Light switch is defective Replace light switch UV closure panel not installed Install UV closure panel UV lights only Magnetic switch for UV closure panel defective Replace switch UV lights only UV timer circuit board defective Replace circuit board UV lights only UV light timer does not work PCR ...

Page 23: ...Product Service 1 800 522 7658 19 APPENDIX A REPLACEMENT PARTS The following illustrations indicate the replacement parts ...

Page 24: ...crew 10 24 x 1 00 PH SS 11A 1 3929400 Label Tissue Culture Enclosure 11B 1 3929500 Label PCR Enclosure 12 1 3945300 Timer Digital UV PCB 13A 1 1307000 Switch 2 position Aux Outlet 13B 1 1306300 Switch 3 position Light 14 1 9721901 Lamp Fluorescent FT25T8 25 Watt 15 1 1271300 Lamp UV G30T8 30 Watt 16 1 1294000 Ballast Fluorescent 17A 1 1233400 Ballast UV 115V 17B 1 1233600 Ballast UV 230V 18A 2 133...

Page 25: ...Appendix A Replacement Parts Product Service 1 800 522 7658 21 Figure A 1 Figure A 2 16 17 9 20 Interior 18 19 21 12 14 15 Interior 8 13 11 13 Light 3 Pos 10 2 6 3 5 5 4 7 1 22 24 22 23 ...

Page 26: ...Product Service 1 800 522 7658 22 APPENDIX B DIMENSIONS See the following dimensions ...

Page 27: ...rature range 41 to 104 F 5 to 40 C Maximum relative humidity 80 for temperatures up to 88 F 31 C decreasing linearly to 50 relative humidity at 104 F 40 C Main supply voltage fluctuations not to exceed 10 of the nominal voltage Transient over voltages according to Installation Categories II Over voltage Categories per IEC 1010 Temporary voltage spikes on the AC input line that may be as high as 15...

Page 28: ...Product Service 1 800 522 7658 24 ...

Reviews: