LAB IPD SERIES Quick Start Manual Download Page 3

3

Introduction

Lab.gruppen IPD Series amplifiers provide exceptionally high power density and powerful integrated DSP features, making them suitable for a 

broad range of installed and touring sound applications. All IPD Series amplifiers feature both analog and AES3 inputs with link outputs; input 

mixing; comprehensive DSP functions (crossover, parametric EQ, delay and limiter control); network control via Ethernet on Cat-5 cable or using 

suitable WiFi access point; IntelliDrive™ Controller software and iPad native app; comprehensive front-panel display and dedicated mute buttons; 

and both binding post and Neutrik speakON output connectors.

The information contained in this Quick Start Guide is sufficient for proper installation of IPD Series amplifiers, and for configuration of settings 

in typical applications. Please refer to the full Operation Manual for detailed information on maintenance, cooling requirements, warranty, and 

configuration for complex installations. 

Except as specifically noted, all features, values and connections are identical for the IPD 1200 and IPD 2400.

Important safety instructions

1.   Read these instructions. 

2.   Keep these instructions.

3. 

  Heed all warnings.

4. 

  Follow all instructions.

5. 

  Do not use this apparatus near water.

6. 

  Clean only with a dry cloth.

7. 

  Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.

8. 

  Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat.

9. 

  Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. 

A grounding-type plug has two blades and a third grounding prong. 

The wide blade or the third prong is provided for your safety. If the 

provided plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10.  Protect the power cord from being walked on or pinched, particularly 

at plugs, convenience receptacles, and the point where they exit 

from the apparatus. 

11. 

Only use attachments/accessories specified by the manufacturer.

12. 

Use only with a cart, stand, tripod, bracket, or table specified by the 

manufacturer, or sold with the apparatus. When a cart is used, use 

caution when moving the cart/apparatus combination to avoid injury 

from tip-over. 

13. 

Unplug this apparatus during lightning storms or when unused for 

long periods of time.

14. 

Refer all servicing to qualified service personnel. Servicing is required 

when  the  apparatus  has  been  damaged  in  any  way,  such  as 

 

power-supply cord or plug is damaged, liquid has been spilled or 

objects  have  fallen  into  the  apparatus,  the  apparatus  has  been 

exposed to rain or moisture, does not operate normally, or has been 

dropped.

15. 

WARNING: To reduce the risk of fire of electric shock, do not expose 

this apparatus to rain or moisture. 

16. 

Do not expose this equipment to dripping or splashing and ensure 

that no objects filled with liquids, such as vases, are placed on the 

equipment. 

17. 

Do not connect the unit’s output to any other voltage source, such 

as battery, mains source, or power supply, regardless of whether the 

unit is turned on or off. 

18. 

Do not remove the top (or bottom) cover. Removal of the cover will 

expose hazardous voltages. There are no user serviceable parts 

inside and removal may void the warranty. 

19. 

An experienced user shall always supervise this professional audio 

equipment, especially if inexperienced adults or minors are using 

the equipment. 

Standard

This equipment conforms to the 

requirements of the EMC Directive 

2004/108/EC and the requirements of 

 

the Low Voltage Directive 2006/95/EC.

Standards applied: EMC Emission 

EN55103-1, E3

EMC Immunity EN55103-2, E3, with S/N 

below 1% at normal operation level.

Electrical Safety EN60065, Class I. 

This equipment is tested and listed 

according to the U.S. safety standard 

ANSI/ UL 60065 and Canadian safety 

standard CSA C22.2 NO. 60065. UL 

made the tests and they are a Nationally  

Recognized Testing Laboratory (NRTL).

 

Explanation of graphic symbols 

The lightning bolt triangle is used to 

alert the user to the presence of 

un-insulated “dangerous voltages” 

within the unit’s chassis that may be 

of sufficient magnitude to constitute a 

risk of electric shock to humans.

The exclamation point triangle is used to 

alert the user to presence of important 

operating and service instructions in the 

literature accompanying the product.

To prevent electric shock do not remove top or bottom covers. No user 

serviceable parts inside. Refer servicing to qualified service personnel.

To  completely  disconnect  this  equipment  from  the  AC  mains, 

disconnect  the  power  supply  cord  plug  from  the  ac  receptacle. 

 

The mains plug of the power supply cord shall remain readily operable.

Summary of Contents for IPD SERIES

Page 1: ...1 Quick Start Guide Guide de prise en main Das Wichtigste in K rze Gu a de Inicio R pido IPDSERIES TouringandInstallationAmplifiers Rev 2 1 1 Item no QSG IPD...

Page 2: ...2 Contents English Quick start guide Chinese Japanese French Guide de prise en main German Das Wichtigste in K rze Spanish Gu a de Inicio R pido 3 11 19 27 35 43...

Page 3: ...the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service perso...

Page 4: ...port brackets are included and use is recommended in all applications Cooling Please ensure that there is sufficient space in the front and the rear of each amplifier to allow for a free flow of air N...

Page 5: ...ndicators Level Horizontal VU meters for each channel Device name and Preset name In setup mode the display shows currently selected menu locations and parameters For more information on DSP setup pro...

Page 6: ...ctor This is an active link which sends an unprocessed AES3 loop thru to feed additional IPD units The design requires no termination load when the unit is the last connected Fig 1 Channel 1 sent thro...

Page 7: ...Limiter Clip Limiter Rail Sense Limiter SCVPL X Over Input 2 Levels Input 2 EQ Input 2 delay Output 2 Levels Output 2 EQ IDEEA Amplifier PSU Output 2 Delay SCVPL X Over Input Mixer Fig 3 Presets Load...

Page 8: ...ed individually to the router Wireless Router Cat 5e iPad Tablet iPad PC or Mac Computer Cat 5e direct connection may require crossed cable or MDI X capable NIC Network Router Cat 5e PC Mac PC Mac Net...

Page 9: ...evice header panel appears at the top of each configuration window for a selected device The header panel accesses the following functions and information Return to Global Power on off Output mute per...

Page 10: ...ble per channel The Output EQ view accesses the following functions Parametric equalizer up to 10 bands High pass filter Low pass filter Output level and limiting status Output delay up to 2 sec Cross...

Page 11: ...4 15 16 17 18 19 2004 108 EC 2006 95 EC EMC EN55103 1 E3 EMC EN55103 2 E3 1 EN60065 I ANSI UL60065 CSA C22 2 NO 60065 UL NRTL 2 Lab gruppen IPD DSP IPD AES3 DSP EQ Cat 5 WiFi IntelliDrive iPad Neutrik...

Page 12: ...12 3...

Page 13: ...13 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6...

Page 14: ...14 5 Channel 1 sent through to top box Channel 2 Channel 1 and 2 Channel 1...

Page 15: ...tput 2 EQ IDEEA Amplifier PSU Output 2 Delay SCVPL X Over Input Mixer Presets Load Store Meters Mixer I O Meters Input 1 2 Gain Delay Link Imput Mixer Device Config Mode Lock LCD Brightness Device Nam...

Page 16: ...16 7 Wireless Router Cat 5e iPad Tablet iPad PC or Mac Computer Cat 5e direct connection may require crossed cable or MDI X capable NIC Network Router Cat 5e PC Mac PC Mac...

Page 17: ...17...

Page 18: ...18...

Page 19: ...e l int rieur Tous reparations doit etre faire par personnel qualifi seulment Fran ais Pour d monter compl tement l quipement de l alimentation g n rale d monter le c ble d alimentation de son r cepta...

Page 20: ...jet rempli de liquide tel que des vases ne doit pas tre plac sur l appareil Fran ais Cet appareil doi t tre raccord une prise de courant qui est branch e la terre Fran ais Lorsque la prise du r seau d...

Page 21: ...ED 1 5 7 ADJUST SET 8 VU DSP 1 2 3 4 5 6 7 8 1 BALANCED INPUTS ANALOG LINK XLR F XLR M 2 AES EBU LINK AES3 AES3 XLR F XLR M 3 RJ45 Win Mac iPad WiFi LINK LED ACT LED 4 CHANNEL 1 4 1 1 2 CHANNEL 2 2 5...

Page 22: ...6 dBu 1 1 2 3 IPD AES3 AES3 XLR F 110 XLR 110 AES3 IPD IntelliDrive Controller AES3 AES3 XLR M IPD AES3 IPD AES3 1 Channel 1 sent through to top box Channel 2 Channel 1 and 2 Channel 1 IPD Neutrik 2 2...

Page 23: ...2 Levels Output 2 EQ IDEEA Amplifier PSU Output 2 Delay SCVPL X Over Input Mixer 3 Presets Load Store Meters Mixer I O Meters Input 1 2 Gain Delay Link Imput Mixer Device Config Mode Lock LCD Brightn...

Page 24: ...Cat 5 IPD WiFi IntelliDrive Controller iPad IPD IPD Wireless Router Cat 5e iPad Tablet iPad PC or Mac Computer Cat 5e direct connection may require crossed cable or MDI X capable NIC Network Router Ca...

Page 25: ...25 8 Global GLOBAl UI Device Header GLOBAL IP Input Mixer INPUT MIXER 2 AES Levels...

Page 26: ...26 9 Input EQ EQ EQ INPUT EQ EQ EQ 10 2 Output EQ EQ EQ OUTPUT EQ EQ EQ 10 2 Crossover X Over X OVER...

Page 27: ...la pluie ou l humidit s il ne fonctionne pas normalement ou s il est tomb 15 AVERTISSEMENT pour r duire le risque d incendie ou d lectrocution n exposez pas cet appareil la pluie ni l humidit 16 N exp...

Page 28: ...D 2400 La profondeur est de 360 mm avec l querre de rack en face arri re Le poids est d environ 6 2 kg Les querres de soutien arri re sont incluses et leur emploi est recommand dans toutes les applica...

Page 29: ...nts Niveau VU m tres horizontaux pour chaque canal Nom d appareil et nom de preset et param tres de menu actuellement s lectionn s Pour plus vous r f rer au mode d emploi Facearri re Les connecteurs s...

Page 30: ...Renvoi AES3 LINK Un connecteur XLR M loquet est mont c t du connecteur d entr e AES3 C est un renvoi actif qui assure le renvoi du signal AES3 sans traitement pour servir de source des unit s IPD sup...

Page 31: ...ur de tension de rail SCVPL Crossover Entr e 2 Niveaux Entr e 2 galiseur Entr e 2 D lai Sortie 2 Niveaux Sortie 2 galiseur Amplificateur IDEEA Alimentation lectrique Sortie 2 D lai SCVPL Crossover M l...

Page 32: ...Le r seau IPD n emploie qu une topologie en toile Chaque Routeur sans l Cat 5e iPad tablette iPad Ordinateur PC ou Mac Cat 5e la connexion directe peut n cessiter un c ble crois ou une carte r seau a...

Page 33: ...ra t en haut de chaque fen tre donne acc s aux fonctions et informations suivantes Retour la fen tre Global Allumage extinction Coupure du son de sortie par canal Nom d appareil Indication en ligne ho...

Page 34: ...ondes galiseur de sortie La fen tre de l galiseur de sortie peut tre s lectionn e par canal La fen tre de l galiseur de sortie donne acc s aux fonctions suivantes galiseur param trique jusqu 10 bandes...

Page 35: ...en insbesondere am Ger t selbst sowie an dessen Netzstecker 11 Verwenden Sie nur vom Hersteller benannte Erg nzungen und Zubeh rteile f r dieses Ger t 12 Verwenden Sie nur die vom Hersteller als geeig...

Page 36: ...as Gewicht betr gt circa 4 6 kg Die Verwendung r ckseitiger Halterungen ist bei Festinstallationen nicht erforderlich sollte beim anspruchsvollen Tourbetrieb aber in Erw gung gezogen werden IPD 2400 D...

Page 37: ...orizontale VU Meter f r jeden Kanal Ger tename und Presetname Im Setup Modus zeigt das Display die gerade ausgew hlten Men po sitionen und Parameter Weitere Informationen ber das DSP Setup Verfahren e...

Page 38: ...r Verf gung Dies ist ein aktiver Link ber den das eingehende AES3 Signal unbearbeitet an weite re IPD Ger te weitergeleitet werden kann Diese Schaltung erfordert beim letzten Ger t keinen Abschlusswid...

Page 39: ...Output 1 EQ IDEEA Amplifier Output 1 Delay Clip Limiter Clip Limiter Rail Sense Limiter SCVPL X Over Input 2 Levels Input 2 EQ Input 2 delay Output 2 Levels Output 2 EQ IDEEA Amplifier PSU Output 2 D...

Page 40: ...rst rker muss einzeln mit dem Router verbunden werden WLAN Router Cat 5e iPad Tablet iPad Computer PC oder Mac Cat 5e Direktverbindung erfordert ggf gekreuztes Ethernetkabel oder MDI X f higes Interfa...

Page 41: ...en Rand jeder Kon figurationsseite des ausgew hlten Ger tes angezeigt Mit der Ger tekopfzeile k nnen Sie auf die folgenden Funktionen und Informati onen zugreifen Zur ck zur globalen Ansicht Ger t an...

Page 42: ...teht eine eigene Ausgangs EQ Ansicht zur Verf gung In der Ausgangs EQ Ansicht k nnen Sie auf die folgenden Funktionen zugreifen Parametrischer Equalizer mit bis zu 10 B ndern Hochpassfilter Tiefpassfi...

Page 43: ...rato para evitar da os en caso de un vuelco 13 Desconecte este aparato durante las tormentas el ctricas o cuando no lo vaya a usar durante un periodo de tiempo largo 14 Consulte cualquier posible aver...

Page 44: ...abrazaderas de soporte traseras opcionales en aplicaciones en giras en directo con muchas actuaciones IPD 2400 Tiene una profundidad de 360 mm desde el asa de rack al panel trasero Su peso es aproxim...

Page 45: ...ivel Medidores VU horizontales para cada canal Nombre de dispositivo y de preset posici n de men activos Para m s informaci n acerca de los Paneltrasero En el panel trasero encontrar los siguientes co...

Page 46: ...anche al lado del conector de entrada AES3 Esto es un enlace activo que env a una se al AES3 loop thru sin procesar para dar se al a unidades IPD adicionales El dise o no requiere ninguna carga de ter...

Page 47: ...turaci n Limitador de saturaci n Limitador de sensibilidad de ra l SCVPL X Over Entrada 2 Niveles Entrada 2 EQ Entrada 2 Retardo Salida 2 Niveles Salida 2 EQ Amplificador IDEEA PSU Salida 2 Retardo SC...

Page 48: ...software IntelliDrive Controller debe ser conectado individualmente al router Router inal mbrico Cat 5e iPad Tableta iPad Ordenador PC Mac Cat 5e la conexi n directa puede requerir un cable cruzado o...

Page 49: ...les del bus de mezcla de entrada Niveles de salida Limitadores de salida Enlace de entradas y salidas 8 Global La ventana Global le muestra todos los dispositivos de la red y le da acceso a las funcio...

Page 50: ...canal La ventana Output EQ le da acceso a las siguientes funciones Ecualizador param trico hasta 10 bandas Filtro pasa altos Filtro pasabajos Nivel de salida y estado del limitador Retardo de salida...

Page 51: ......

Page 52: ...lidrive IPD and Intelligent Power Drive are trademarks of Lab gruppen AB All other trademarks remain the property of their respective owners Copyright 2013 Lab gruppen AB All rights reserved labgruppe...

Reviews: