N
EO
T
HERM
Residential Boilers
®
Quick Start
This menu gives you an easy way to check or change the most common set-
tings on the unit:
• CH setpoint
• DHW setpoint
• Outdoor reset
• Low water temperature
• Maximum outdoor temperature
• Minimum outdoor temperature
• Adjustable high limit
• Adjustable low limit
See Section 8B for more information.
Login
If you want to change a setup value or function, and the system requires a
password, you can enter it here. See the section on “Login Display.”
Test
These parameters let you turn the burner on and off, and control the fan and
pump speeds. See the section on “Test Menu.”
Advanced Setup
The sub-menus listed here allow you to set up most of the functions on the
controller. In the section on “Advanced Setup” we will explain how to reach all
of the setup functions. (For many of these functions, the system will require a
password before it will allow you to make changes.)
Diagnostics
Use the Diagnostics to check the status of the sensors and the digital inputs
and outputs. The system also records a history of lockouts and alarms. See
the section on “Diagnostics.”
Display Setup
You can use this option to adjust the contrast of the display or change the
items which appear at the top of the Home display. See the section on
Display Setup.
Table 17. - Functions on Info/ Install Menu
• Press the round OK button to select that line.
Figure 23
shows a typical screen for this type of setting.
Figure 23. – Changing a Value
• The current setting for the setpoint appears in the box
at the top of the screen. In this example, this is 182°F.
• The numbers near the left edge of the screen show the
allowable range for this value. In this case, the setpoint
can be set anywhere between 240°F and 32°F.
• Press the Up- and Down-Arrow buttons to scroll the
setpoint until you see the correct value in the box.
• When the value is correct, press the round OK button.
You will notice that the system did not ask you for a
password, so this is one of the values that can be changed
by anyone.
Entering a Time
The controller uses several different timing functions,
and you can change some of these. (In this example,
we will use the screen for the Anti Short-Cycle Time.
Figure 24. - Changing a Timing Function
• The current setting appears in the upper right-hand
corner of the screen. In this example, this is 1
minute.
• The numbers near the left edge of the screen show
the allowable range for this value. In this case,
the time can be set anywhere between 0 seconds
Summary of Contents for NEOTHERM NTH Series
Page 4: ...LAARS Heating Systems...
Page 24: ...Page 24 LAARS Heating Systems Figure 9 Hydronic Piping Single Boiler Zoning with Circulators...
Page 33: ...Page 33 NEOTHERM Residential Boilers Figure 16 Control Panel Layout...
Page 38: ...Page 38 LAARS Heating Systems Figure 19 Ladder Diagram 7 H Ladder Diagram...
Page 67: ...Page 67 NEOTHERM Residential Boilers Figure 44 Heat Exchanger Components 68A 65 67 60 66 63 64...
Page 68: ...Page 68 LAARS Heating Systems Figure 45 Electrical Components...
Page 82: ...LAARS Heating Systems Notes...