LAARS Heating Systems
Page 22
Figure 10B. W
iring Diagram, JVS
R
C
URVE
WWSD
DHW CALL
HEAT CALL
POWER
1
2
3
4
BO
ILER
SEN
SOR
SYS
COM
OUT
HEAT CALL
COM
CA
LL
DHW CALL
120 VAC L
SWITCHED 120 VAC TO PUMP
0.4
2.0
3.6
1 2 3 4
O
FF O
N
FIELD WIRING
IN
DUCER FA
N
BK
BL
H
C
MV
PV
24V 115V
TRANSFORMER
(220V OPT)
SPARK
2 MV/PV
IGNITION CONTROL
9 SPARK
8 MV
7 TH-W
6 24V
5 24 V (GR)
4 GND
3 PV
1 MV
TEMPERATURE
SENSOR
BOX DIVIDER
FROM REAR OF BOARD.
NOTE: 1.
4-PIN
MOLEX
AS
VIEWED
R
R-ROUGE
R-RED
W-BLANC
W-WHIT
E
Y-YELLOW
Y-JAUNE
BL-BLUE
O-ORANGE
BR-BR
UN
BR-BROWN
BL-BLEU
O-ORANGE
P-PURPLE
P-MAUVE
G-GREEN
Capteur
BK-NOIR
(Field
Supplied)
Câbles
De
Volet
Motorisé
D'Électrode À Étincelles
BK-BLACK
Bl
oc
ke
d
Pompe À Chaleur (Fourni
Lors
De
L'Installation)
Vent
Damper
Receptacle
Prise
Du
Faisceau
De
De Retour
HW
V
R8
30
4
Vent Safety
De Falmme
G
-V
ER
T
Switch
Ro
ll-
O
ut
Boiler
Pump
5A
Max
Soupape De Gaz
Switch
Limiteur
G
as
Valve
HW
VR8304
À
Air
Pulsé
(Voir
Manuel)
Prise
De
Ventilation
Se
e
Do
c.
1
07
7
Power
Venter
Receptacle
Hi
gh
L
im
it
Limite
Supérieure
Veilleuse À
Electrode Sensor
with Spark
Pilot Burner
THE BOILER WILL NOT OPERATE W
IT
HO
UT
T
HE
A
UT
O
M
A T
IC
V
EN
T
DAMPER. THE VENT DAMPER WIRE HARNESS MUST BE INSERTED INTO THE VENT DAMPER RECEP
TACLE.
IN CANADA:
SOME UNITS ARE
SUPPLIED WITH VENT DAMPER JUMPER PLUG. DO NOT REMOVE JU
M
PE
R U
NL
ES
S V
ENT
D
AM
PE
R
IS TO BE INSTALLED.
LA CHA
UD
IÈRE NE FON
CTI
ONNERA
PAS SANS LE VOLET MOTORISÉ AUTOMATIQUE. LE F AISCEAU DE CÂBLES DU VOLET MOTORISÉ DOIT ÊTRE INSÉRÉ DANS LA PRISE DU VOL
ET MOTORISÉ
AU CANADA: CERTAINS A
PPAREILS
SONT MUNIS D’UN CAVAL IER DE VOLET MOTORISÉ. NE PAS RETIR ER LE CAVALLIER À MOINS Q UE LE VOLET MOTORISÉ NE SOIT INST ALLÉ
BK (2-STAGE ONLY)
FUSE
BL
BK
P
Y
Y
Y
BR
Y
O
Y
REMOTE FLAME SENSOR
BK
BK
BK
R
Y
YW
BK
R
R
R
R
A LA TERRE
CAVALIER
JUMPER
W
HOT CHAUD 115/60Hz (220V/50Hz OPTIONAL) POWER SUPPLY
NE
UT
RA
L
NEUTRE
GROUNDING CONDUCTOR CABLE DE MISE
(2-STA
GE ONLY)
1
JV
S
E2
3445
D
C
B
A
B
C
D
1
2
3
4
DE
CI
M
AL
S .
XX
1
/8"
.1
4
3
2
BY
LA
AR
S H
EA
TIN
G SYSTE
M
S.
FMA
56A
DWG
NO.
SH
1
RE
V
A
CJ 5-23-1
2
RE
VIS
IO
NS
REV
.
CH
AN
GE:
APPR
ENGR
A
PPR
ECN
DRAFT
CH
ECK
UPDA
TE
D W
IRES
TO
4
-PIN M
O
LE
X C
O
NNEC
TO
R
A
12-03
2N
-01
PM
5-23-1
2
S
C
AL
E: NO
NE
INT
ENDED S
IZE
:
SOFTW
AR
E
DW
G
. N
O
:
C
SH
EET
1
OF 1
REV
.
APPROV
AL
S
DR
AF
T
DECI
MA
LS .X
TITL
E:
REP
RO
DUCED
, T
RA
NS
FERRED
TO
O
THER D
O
CUM
ENT
S, US
ED
O
R
DISCLOSE
D T
O OT
HE
RS
FOR
MA
NU
FA
CT
UR
IN
G OR
A
NY
OT
HE
R
DIM
ENS
IO
NS
A
RE IN INC
HES
.
TO
LE
RA
NCE
S
AR
E:
MA
TERIA
L:
FIN
ISH
N/
A
N/
A
PM
9
-20-1
1
ENG
R
.0
10
S
AP
PR
UN
LESS OT
HE
RWI
SE SP
ECI
FIE
D:
PU
RPOS
E EX
CEPT
A
S S
PECIFICA
LLY
A
UT
HORIZ
ED IN WRIT
ING
D
EC
IM
AL
S .
XXX
TH
IRD A
NGL
E PROJECT
ION.
PR
OPR
IET
AR
Y TO LA
AR
S H
EA
TIN
G SYSTE
MS A
ND
SH
ALL N
O
T B
E
DO
NO
T S
C
AL
E DRA
W
ING.
.0
3
TH
IS DO
CU
M
ENT
A
ND T
HE INF
O
RM
AT
IO
N CO
NT
AI
NED HEREIN A
RE
AN
GLES
FRA
C
TIONS
W
IRING
DIA
G
RA
M
A