background image

Page 3

Figure 1. Heater Identification (model nomenclature).

WARNING

This pool heater must be installed in accordance 

with the procedures outlined in this manual. The 

warranty does not apply to pool heaters not installed 

or operated in accordance with these procedures. 

Consult local building and safety codes before 

proceeding with work. The installation must conform 

to the requirements of the authority having jurisdiction 

or, in the absence of such requirements, to the latest 

edition of the National Fuel Gas Code; ANS1 Z223.1, 

National Electrical Code ANSI/NFPA 70 and/or in 

Canada CAN1-B149 requirement.

When required by the authority having jurisdiction, 

the installation must conform to American Society of 

Mechanical Engineers safety codes for controls and 

safety devices for automatically fired heaters No. 

CSD-1, and in Canada CGA 3.3. Any modification to 

the water heater, its gas controls, gas orifices, wiring 

or draft diverter may void the Laars warranty. If field 

conditions require such modifications, consult factory.

1.3  Heater Identification

Consult rating plate on the heating heater. Shown 

in Figure 1 is a breakdown of the model nomenclature. 
This commercial pool heater is available in two 

configurations: an indoor version and an outdoor version. 

Outdoor models are not available in Canada. 

1.4  Primary/Secondary Pump and Piping

All models are supplied with integrally mounted 

pumps. The 1825 models use a 3/4 HP pump and all 
other models are supplied with 1/2 HP pumps. These 
pumps are sized for the pressure drop through the heat 
exchanger and through the bypass piping as shown in 
Figure 10.

Any deviations from the arrangement shown may 

increase the head on the pump, reduce flow and hinder 

performance (see Section 2.7). For spas see Section 3.9.

This piping arrangement and the integral pump 

allow hot water to be recirculated to the heater inlet, 
thus raising the inlet temperature and greatly reducing 
condensation.

MightyTherm Pool Heater

REVISION

P

-PUMP (U.S.)

Q

-PUMP (CAN)

HEAT EXCHANGER

C

-GLASS LINED/COPPER

N

-GLASS LINED/CU-NI

A

-GLASS LINED/COPR REVRSD

M

-GLASS LINED/CU-NI REVRSD

Option Code

XX

 - Standard

JX

 - CSD-1

HL 

 -  High & low gas 

pressure switches

LC

  -  LWCO 

 

& 100% lockout

LW 

- LWCO

VERSION

1

 - 8 TUBE

B

-10 TUBE

I

-INDOOR

E

-OUTDOOR

FUEL

N

-NATURAL

P

-PROPANE

IGNITION

04

-SPARK 110V

09

-SPARK 24V

11

-SPARK 24V

16

-STND. PILOT

SIZE-MBTU/h

0500
0600
0715
0850
1010
1200
1430
1670
1825

FIRING MODE
ON/OFF

  1 

5  6 

9  10 

11 

12 

13 

14 

      15  16

MODEL

AP

- MIGHTY THERM POOL

SECTION 1.
General Information

1.1 Introduction

 
 

This manual provides information for the 

installation and operation of Mighty Therm, model 
AP pool heaters. It is strongly recommended that 
all application and installation procedures be 
reviewed completely before proceeding with the 
installation. Consult the Laars factory, or local factory 
representative, with any problems or questions 
regarding this equipment. Experience has shown that 
most problems are caused by improper installation, not 
system design.
  

Some accessory items are shipped in separate 

packages. Verify receipt of all packages listed on the 
packing slip. Inspect everything for possible damage 
upon delivery, and inform the carrier of any shortages 

or impairments. Any such claims should be filed with 

the carrier. The carrier, not the shipper, is responsible 
for shortages and damage to the shipment whether 
visible or concealed.

1.2  Warranty

Laars Heating Systems appliances are covered 

by a limited warranty. Owners should submit online 
warranty registration at 

www.Laars.com

.

All warranty claims must be made to an authorized 

Laars Heating Systems representative, directly to 
Customer Service, or online at 

www.Laars.com

Claims must include the serial number and model 
number (this information can be found on the rating 
plate), installation date, and name of the installer. 
Shipping costs are not included in the warranty coverage.

WARNING

The Model AP commercial pool heater must be used 

on potable water only. For heating pools containing 

salt water, a specially equipped heater must be used; 

consult your distributor or factory representative. The 

pool heater must be installed in accordance with the 

procedures outlined in this manual.

A P

C

Summary of Contents for Mighty Therm AP

Page 1: ...pas tenter d allumer d appareils Ne touchez aucun interrupteur Ne pas vous servir des t l phones dansle b timent o vous vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Su...

Page 2: ...or Pool Heaters 7 2 4 Gas Supply and Piping 7 2 5 Electrical Wiring 8 2 6 General Piping Instructions 9 2 7 Heater By Pass Piping 9 2 8 Temperature Sensor Placement and Installation 10 2 9 Automatic C...

Page 3: ...N HEAT EXCHANGER C GLASS LINED COPPER N GLASS LINED CU NI A GLASS LINED COPR REVRSD M GLASS LINED CU NI REVRSD Option Code XX Standard JX CSD 1 HL High low gas pressure switches LC LWCO 100 lockout LW...

Page 4: ...of ANSI standard Z223 1 and any local codes that may be applicable Inadequate combustion air supply may result in incomplete combustion sooting of the heat exchanger and unsafe operation of the heate...

Page 5: ...and must not be connected to any portion of a mechanical draft system under positive pressure The flue outlet must be connected to a clear unobstructed vent of adequate capacity ending above the high...

Page 6: ...ing system are located and the other spaces of the building Turn on any clothes dryer and any appliance not connected to the common venting system Turn on any exhaust fans including range hoods and ba...

Page 7: ...or wall recess Avoid locations where wind deflection off structures might cause downdraft When such wind conditions are possible place the heater at least 3 feet 0 9m from the structures 3 Never insta...

Page 8: ...cifically ordered otherwise 2 The 1825 models are supplied with 3 4 HP pump motors All other models are supplied with 1 2 HP pump motors Consult the National Electrical Code or the Canadian Electrical...

Page 9: ...ilter system are made of plastic materials they may be damaged by the momentary back siphoning of hot water from the heater when the filter pump stops running The pressure relief valve installed in th...

Page 10: ...Controls a Intermittent Ignition Pilots are automatically lit when the operating control calls for heat Systems 4 9 and 11 The unit performs its own safety check and opens the main valves only after...

Page 11: ...e auto reset limit switch is provided as standard equipment on all heaters The temperature sensing bulb of the switch is field installed and should be located in the pool loop piping See Section 2 8 f...

Page 12: ...auses air to be drawn into the heater and the secondary piping an automatic float type air vent should be permanently installed on top of the pump scroll 3 To check the heater firing proceed as follow...

Page 13: ...pen throttle turn down outlet valve B slightly Observe the inlet thermometer for 5 minutes to see where the inlet temperature stabilizes If it remains under 110 F 43 C throttle outlet valve B a little...

Page 14: ...caution is suggested for young children adjusted incrementally to obtain the desired pool operating temperature 7 An adjustable pump time delay relay is mounted in the control panel see Figure 11 Thi...

Page 15: ...30 days 90 days and once every six months thereafter Fouling on the external surfaces of the heat exchanger is caused by incomplete combustion and is a sign of combustion air and or venting problems...

Page 16: ...operating condition and preventing corrosion liming or other problems Proper pool water chemistry includes other values that must be maintained for swimmer safety Refer to your local agency having jur...

Page 17: ...r u s s e r p m o r f y r a s s e c e n s a t s u j d a F Electric gas valve operator is F Disconnect wiring harness at gas valve terminals Check continuity of actuator burned out or shorted coil If o...

Page 18: ...303 10548301 14 Tile Heat Shield Spacer Rear 10548401 10548402 10548403 10548404 15 Saddle Assembly End Tile 10533600 10533600 10533600 10533600 10533600 10533600 10533600 10533600 10533600 2 2 2 2 2...

Page 19: ...Page 19 Figure 17 Parts Identification Mighty Therm Commercial Pool Heating Boiler Page 19 Figure 17 Parts Identi cation ONE PIECE PUMP VOLUTE MightyTherm Pool Heater...

Page 20: ...n Combustible Base Rail 10539000 10539000 10539000 10539000 10539000 10539000 10539000 10539000 10539000 2 2 2 2 2 2 2 2 2 Water System 34 8 Tube Assembly Copper Tubes 10534701 10534702 10534703 10534...

Page 21: ...101 2 2 2 2 2 2 2 2 2 42 Flange Gasket S0063700 S0063700 S0063700 S0063700 S0063700 S0063700 S0063700 S0063700 S0063700 2 2 2 2 2 2 2 2 2 43 Header Gasket w Barrier S0095100 S0095100 S0095100 S0095100...

Page 22: ...00 58 Pilot Bracket Burner Weldment 10529502 10529502 10529502 10529502 10529502 10529502 10529502 10529502 10529502 59 Pilot Burner W0035800 W0035800 W0035800 W0035800 W0035800 W0035800 W0035800 W003...

Page 23: ...Control Electronic E2305400 E2305400 E2305400 E2305400 E2305400 E2305400 E2305400 E2305400 E2305400 Single Try 72 Transformer 115V 24V R0021300 R0021300 R0021300 R0021300 R0021300 R0021300 R0021300 R0...

Page 24: ...ssemblies When ordering tiles Assembly number is for all tiles Part numbers shown for the front of unit are the same for the rear tiles Check dimensions of old tile as shown here to confirm part numbe...

Page 25: ...Page 25 Figure 19 Outdoor Parts 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 13 20 MightyTherm Pool Heater...

Page 26: ...10665907 10665908 10665909 Copper Tube Cast Iron Tubs Outdoor 10 Tube Assembly 20001101 20001102 20001103 20001104 20001105 20001106 20001107 20001108 20001109 Copper Tube Bronze Tubs Outdoor 10 Tube...

Page 27: ...Front End Panel 10657501 10657501 10657501 10657501 10657501 10657501 10657501 10657501 10657501 13 Right Front End Panel 10657502 10657502 10657502 10657502 10657502 10657502 10657502 10657502 10657...

Page 28: ...905 636 0666 www Laars com Litho in U S A Laars Heating Systems 21 10 Document 3006V Laars Heating Systems Company reserves the right to change specifications components features or to discontinue pro...