DHW Set Point Change Modes

Page 54

5.4 

Status Display Mode

Digital Display

Status Display Parameter 

Description 

O:ot

Outdoor temperature

Current Outdoor temperature

A: Li or A: GA 

Flow unit 

Current fl ow value(Li: L/m, GA: GPM) 

b: It 

CH Return Water Temperature Current Return Water Sensor Temperature

C: Fr 

Fan rpm 

Current fan rpm value 

d: Lc 

Lock mode 

Lock mode ON/OFF 

E: oP 

OP temperature 

Current OP temperature 

F: dH 

DHW temperature 

Current DHW temperature 

H: Eh 

Exhaust temperature 

Current Exhaust temperature 

I : St

N/A

Not Used (Default is 0) 

J: oH 

Overheat temperature 

Current Overheat temperature 

L: rt 

1: PH

Burner 

Operation 

Time

Supply power 

time

Supply power time x 100 hour

2: rh

Burner 

operation time

Burner operation time x 1 hour

3: rH

Burner 

operation time

Burner operation time x 1,000 hour

4: It

Ignition cycles

Ignition cycles x 10 times

5: IH

Ignition cycles

Ignition cycles x  10,000 times

P: Ou

Displays output condition for 

internal primary pump and 

three way valve.

 

- Off 

- On

1st Icon

2nd Icon

3rd Icon

Not Used

Internal  CH 

Pump

3 Way Valve

E

55page

56page

B

C

A

D

To view any of the above listed Status Parameters, 

Press and Hold Button B 

 to get into the Status Display Mode. 

Rotate Dial E until you fi nd the Parameter that you wish to view.  Tap Dial E to enter that Parameter.

 

Adjust to the setting that you require and then press (tap) Dial E to save and to Exit.  

   

Summary of Contents for FT Series

Page 1: ...h could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instructions donn es dans cette notic...

Page 2: ...proper ventilation of interior components Do not obstruct or block a free flow of air to the boiler to ensure proper ventilation If desired clean the jacket surfaces with a damp cloth and mild deterg...

Page 3: ...9 Boiler Pump 10 CH Supply Connection 11 CH Return Connection 12 CH Pressure Gauge 13 DHW Outlet Connection 14 Gas Inlet Connection 15 DHW Inlet Connection filter and flow restrictor 16 Condensate Con...

Page 4: ...age Temperature Range of 20 to 80 C Buttons Function Method Function Method A Display Power Turns Control Display ON OFF Press Tap B Modes Status Display Mode With display power on Press Hold 5 Second...

Page 5: ...y to display all parameters DHW mode Combination boiler Set Point can be adjusted Outside temp or 0 10 V mode Operating by outside temperature or 0 10V Numeric Display Domestic Hot Water Mode Anti Fre...

Page 6: ...hrough a Start Up checklist and briefly show a sequence of diagnostic codes before entering into the Operating Mode It will then display the following information Indicate Example Current Operating Te...

Page 7: ...ture Current Overheat temperature L rt 1 PH Burner Operation Time Supply power time Supply power time x 100 hour 2 rh Burner operation time Burner operation time x 1 hour 3 rH Burner operation time Bu...

Page 8: ...nt changes and to Exit Indicate Example Current DHW set point temperature 120 F Temperature sign Celsius or Fahrenheit letter C or F If display is communicating with the main controller normally the c...

Page 9: ...it When the button D is pressed for more than 5 seconds temperature unit will toggle between C and F To activate heat storage function First turn OFF the power to the Control Display Then Press and Ho...

Page 10: ...Page 10 Notes...

Page 11: ...User s Manual The FT Series Wall Mounted Combination Boiler Page 11 Notes...

Page 12: ...ut notice in accordance with our policy of continuous product improvement Customer Service and Product Support 800 900 9276 Fax 800 559 1583 20 Industrial Way Rochester NH USA 03867 20 10 Document 148...

Reviews: