background image

Page 8

The FT Series Wall Mounted, Combination Boiler

Page 55

5.5 

DHW Set Point Change Mode 

 DHW Set Point Change Modes

The display shows the following 

information when changing water heating 

temperature set points.

* Default DHW set point is 120°F (49°C)

• DHW 95-120°F  (35 - 49°C) LOW range (Default) 

  -To change LOW range, 

press the C Button. The DHW icon and current DHW LOW will fl ash (a fl ashing 

value means it can be changed). 

  -Turn dial E clockwise to increase and counterclockwise to decrease until desired temperature is reached. 

  -Press dial E to save set point changes.

 

• DHW 121 - 140°F (49.5 - 60°C) HIGH range

  -To change HIGH range,

 press and 

HOLD

 the C button for more than 5 seconds. The DHW icon and 

current DHW HIGH will fl ash (a fl ashing value means it can be changed). 

  -Turn dial E clockwise to increase and counterclockwise to decrease until desired temperature is reached. 

  -Press dial E to save set point changes and to Exit. 

Indicate

Example

Current DHW set point temperature

120°F

Temperature sign Celsius or Fahrenheit letter

°C or °F

If  display  is  communicating  with  the  main  controller  normally,  the 

communication icon will be indicated.
When DHW set point range is high : from 121°F (49.5°C) to 140°F (60.0°C)

H . 140°F

When changing DHW set point, the DHW icon will fl ash

S24

Changing between Celsius and Fahrenheit

When the button D     is pressed (for more 

than 5 seconds), temperature unit will toggle 

between °C and °F.

Scalding may occur within 5 seconds at a setting of 140°F (60°C). Water temperatures 

over 125°F can cause severe burns, or death from scalding. Children, disabled, 

and elderly are at highest risk of being scalded. Read all instructions before setting 

temperature at appliance. Feel water before bathing or showering. 

 

Manufacturer strongly recommends the use of an anti-scald mixing valve at 

domestic hot water outlet (boiler location) to reduce potential for scalding. 

Contact Manufacturer for recommended models. Check with local codes.

57page

E

E

B

B

C

C

A

A

D

D

57page

E

E

B

B

C

C

A

A

D

D

DANGER

Summary of Contents for FT Series

Page 1: ...h could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instructions donn es dans cette notic...

Page 2: ...proper ventilation of interior components Do not obstruct or block a free flow of air to the boiler to ensure proper ventilation If desired clean the jacket surfaces with a damp cloth and mild deterg...

Page 3: ...9 Boiler Pump 10 CH Supply Connection 11 CH Return Connection 12 CH Pressure Gauge 13 DHW Outlet Connection 14 Gas Inlet Connection 15 DHW Inlet Connection filter and flow restrictor 16 Condensate Con...

Page 4: ...age Temperature Range of 20 to 80 C Buttons Function Method Function Method A Display Power Turns Control Display ON OFF Press Tap B Modes Status Display Mode With display power on Press Hold 5 Second...

Page 5: ...y to display all parameters DHW mode Combination boiler Set Point can be adjusted Outside temp or 0 10 V mode Operating by outside temperature or 0 10V Numeric Display Domestic Hot Water Mode Anti Fre...

Page 6: ...hrough a Start Up checklist and briefly show a sequence of diagnostic codes before entering into the Operating Mode It will then display the following information Indicate Example Current Operating Te...

Page 7: ...ture Current Overheat temperature L rt 1 PH Burner Operation Time Supply power time Supply power time x 100 hour 2 rh Burner operation time Burner operation time x 1 hour 3 rH Burner operation time Bu...

Page 8: ...nt changes and to Exit Indicate Example Current DHW set point temperature 120 F Temperature sign Celsius or Fahrenheit letter C or F If display is communicating with the main controller normally the c...

Page 9: ...it When the button D is pressed for more than 5 seconds temperature unit will toggle between C and F To activate heat storage function First turn OFF the power to the Control Display Then Press and Ho...

Page 10: ...Page 10 Notes...

Page 11: ...User s Manual The FT Series Wall Mounted Combination Boiler Page 11 Notes...

Page 12: ...ut notice in accordance with our policy of continuous product improvement Customer Service and Product Support 800 900 9276 Fax 800 559 1583 20 Industrial Way Rochester NH USA 03867 20 10 Document 148...