User’s Manual - The FT Series Wall Mounted, Combination Boiler
Page 9
Page 56
To change CH Set point,
press the D
button. The CH Icon and current
CH Set point will fl ash.
Turn the E dial clockwise to increase, and counterclockwise to decrease CH set point, until
desired temperature is reached.
Press E dial to save changes and to Exit.
Default CH set point is 130°F (54°C)
CH set point range is 130 - 180°F (54.4 ~ 82.0°C)
Indicate
Example
Current Operating Temperature
110°F
Temperature sign Celsius or Fahrenheit letter
°C or °F
Display and Controller are communicating
If fl ame detected
If pump is operating
When changing CH Set point, the CH Icon will fl ash
5.6
CH Set Point Change Mode
Changing between Celsius and Fahrenheit
When the button D is pressed (for more than
5 seconds), temperature unit will toggle between
°C and °F.
To activate heat storage function,
First turn OFF the power to the Control Display.
Then Press and Hold Button B
to get into the Installer Mode.
Rota te Dial E until you fi nd
5:St
Tap Dial E to enter Storage Mode. Storage Mode indicates that the boiler is
maintaining the water temperature in the internal storage tank. When Storage Mode is active, the display
will appear as shown.
Turn the E dial clockwise to activate and counterclockwise to deactivate the Heat storage function. Default: ON.
Press E dial to save changes and to Exit.
Indicate
Example
Current Operating Temperature
110°F
Temperature sign Celsius or Fahrenheit letter
°C or °F
Display and Controller are communicating
If fl ame detected
Storage mode indication
If Pump is operating
5.7 Storage Mode