To  change CH Set point,

 press the D 

 

 button. The CH Icon and current 

CH Set point will fl ash. 

Turn  the E dial clockwise to increase, and counterclockwise to decrease CH set point, until 

desired temperature is reached.

Press E dial to save changes and to Exit.  

Default CH set point is 130°F (54°C)   

CH set point range is 130 - 180°F (54.4 ~ 82.0°C)

Indicate

Example

Current Operating Temperature 

110°F

Temperature sign Celsius or Fahrenheit letter

°C or °F

Display and Controller are communicating

If fl ame detected
If pump is operating
When changing CH Set point, the CH Icon will fl ash

5.6 

CH Set Point Change Mode

Changing between Celsius and Fahrenheit

When the button D     is pressed (for more than 

5 seconds), temperature unit will toggle between 

°C and °F.

To activate heat storage function, 

First turn OFF the power to the Control Display. 

Then Press and Hold Button B 

 to get into the Installer Mode. 

Rota  te Dial E until you fi nd  

5:St

    Tap Dial E to enter Storage Mode. Storage Mode indicates that the boiler is 

maintaining the water temperature in the internal storage tank. When Storage Mode is active, the display 

will appear as shown. 

Turn the E dial clockwise to activate and counterclockwise to deactivate the Heat storage function.  Default: ON.

Press E dial to save changes and to Exit.  

Indicate

Example

Current Operating Temperature  

110°F

Temperature sign Celsius or Fahrenheit letter

°C or °F

Display and Controller are communicating

If fl ame detected

Storage mode indication

If Pump is operating

5.7  Storage Mode

58page

E

E

B

B

C

C

A

A

D

D

58page

E

E

B

B

C

C

A

A

D

D

Summary of Contents for FT Series

Page 1: ...h could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instructions donn es dans cette notic...

Page 2: ...proper ventilation of interior components Do not obstruct or block a free flow of air to the boiler to ensure proper ventilation If desired clean the jacket surfaces with a damp cloth and mild deterg...

Page 3: ...9 Boiler Pump 10 CH Supply Connection 11 CH Return Connection 12 CH Pressure Gauge 13 DHW Outlet Connection 14 Gas Inlet Connection 15 DHW Inlet Connection filter and flow restrictor 16 Condensate Con...

Page 4: ...age Temperature Range of 20 to 80 C Buttons Function Method Function Method A Display Power Turns Control Display ON OFF Press Tap B Modes Status Display Mode With display power on Press Hold 5 Second...

Page 5: ...y to display all parameters DHW mode Combination boiler Set Point can be adjusted Outside temp or 0 10 V mode Operating by outside temperature or 0 10V Numeric Display Domestic Hot Water Mode Anti Fre...

Page 6: ...hrough a Start Up checklist and briefly show a sequence of diagnostic codes before entering into the Operating Mode It will then display the following information Indicate Example Current Operating Te...

Page 7: ...ture Current Overheat temperature L rt 1 PH Burner Operation Time Supply power time Supply power time x 100 hour 2 rh Burner operation time Burner operation time x 1 hour 3 rH Burner operation time Bu...

Page 8: ...nt changes and to Exit Indicate Example Current DHW set point temperature 120 F Temperature sign Celsius or Fahrenheit letter C or F If display is communicating with the main controller normally the c...

Page 9: ...it When the button D is pressed for more than 5 seconds temperature unit will toggle between C and F To activate heat storage function First turn OFF the power to the Control Display Then Press and Ho...

Page 10: ...Page 10 Notes...

Page 11: ...User s Manual The FT Series Wall Mounted Combination Boiler Page 11 Notes...

Page 12: ...ut notice in accordance with our policy of continuous product improvement Customer Service and Product Support 800 900 9276 Fax 800 559 1583 20 Industrial Way Rochester NH USA 03867 20 10 Document 148...

Reviews: