background image

 

 

S1 Owner’s Manual 

Page 3 

Basic Machine Operation 

3.1  15A or 20 Amp Operation 

The LaSpaziale S1 is available in 15A and 20A versions. In actuality, they are both 
identical machines.  There is an internal switch that selects the operating mode and 
they have different power cords installed.  The power cord is the easiest way to tell 
which version you have.  The 15A S1 has a standard 3-prong AC plug with two parallel 
blades and a round ground pin.  The 20A S1 has a 3-prong with two perpendicular 
blades and a round ground pin.  The 20A version therefore requires a 20A circuit which 
has a special 20A outlet which accepts the 20A plug.  

Most modern kitchens have 20A circuits.  However, they often do not use 20A outlets 
because multiple outlets may be on the same 20A circuit.  If you have a 20A circuit with 
a 20A outlet this most likely means that outlet has its own dedicated 20A circuit and is 
safe to use with the S1.  A 20A circuit with normal 15A outlets probably means that 
multiple kitchen outlets are on the one 20A circuit.  Often this means the refrigerator 
outlet. 20A S1 owners should contact their electrician if unsure how to proceed.  

The internal switch which places the S1 in 15A mode does so by never allowing the 
group boiler and the steam boiler to operate at the same time.  When the thermostats 
for both boilers try to turn on at the same time, the group boiler always has precedence, 
and then the steam boiler operates in sequential fashion.  A number of 15A S1 owners 
note that they see little operational effect when running in this mode. 

The 20A S1 allows both boilers to operate simultaneously.  HOWEVER, it is possible to 
place the 20A S1 into 15A mode without removing the covers from the machine and 
flipping the internal mode switch.  This is called ECONOMY mode and is described later 
in this manual.  

Economy mode is a great option for those that really want the 20A machine but that do 
not currently have a 20A circuit.  However, this will require swapping out your standard 
15A outlet with a 20A outlet.  These are readily available from most hardware stores. 

3.2  Initial Installation Before Connecting Power 

After removing the S1 from its packing carton and setting it on the counter, check for 
additional installation instructions that may be included.   

Tip the S1 on its side.  Twist all four rubber feet (3) hand tight as they may vibrate loose 
during shipping.  While performing that task, use a screwdriver to ensure that the four 
screws on the bottom (two on each side between the rubber feet) which fasten the two 
side panels (5) to the chassis bottom are tight.  These steps will help ensure the 
quietest possible operation of your S1. 

Be sure you connect the included water hose to the threaded water inlet on the bottom 
of the machine.  Proper connection is obvious since there is only one place it can 
attach.  The opposite end of the hose - which connects to the water supply - may 
require adapters from your local hardware store depending on your specific situation.  

Summary of Contents for S1 Vivaldi

Page 1: ...La Spaziale S1 Vivaldi Double Boiler Espresso Machine Owner s Manual Last Updated on 03 31 2014...

Page 2: ...4 1 Damaged Flow Meter 10 4 2 Damaged Group Temperature Probe 10 4 3 Damaged Boiler Temperature Probe 10 4 4 Damaged Group Heating Element Triac 10 4 5 Damaged Boiler Heating Element Triac 10 4 6 Boi...

Page 3: ...in Safety Thermostat Semi Automatic Hot Water Delivery Manual Steam Valve Fault Diagnosis Alarms Boiler Pressure Gauge Two Complete Portafilter handles Single and Double Baskets Extra shower screens...

Page 4: ...ontrol Panel 16 95 C Lamp 23 Hot Water Button 3 Rubber Feet 10 Group 17 100 C Lamp 24 One Cup Button 4 Boiler Pressure 11 Portafilter Handle 18 105 C Lamp 25 Two Cup Button 5 Side Panels 12 Drip Tray...

Page 5: ...ecedence and then the steam boiler operates in sequential fashion A number of 15A S1 owners note that they see little operational effect when running in this mode The 20A S1 allows both boilers to ope...

Page 6: ...adily for about a second indicating power on test mode 3 The light corresponding to the set temperature starts flashing to indicate that the group is heating and the automatic boiler refill starts unt...

Page 7: ...u choose the desired temperature in order to lock in this value press the ON OFF 27 button the machine will then go back to its normal functioning The value of the operating temperature of the machine...

Page 8: ...e to change it If for example your master temperature setting before entering the fine temperature control mode is 95 C and you press the One Cup 24 button until all three green lamps are lit the wate...

Page 9: ...handle and press it with the included plastic tamper or more optimally a high quality 53mm coffee tamper 3 Fasten the portafilter handle 11 to the brewing group l0 placing a cup under the portafilter...

Page 10: ...eam boiler on and off 2 Entry and exit of Economy mode There are three possible operational modes of the two boilers in the La Spaziale S1 20A model 1 Both boilers are completely independent turning o...

Page 11: ...ing Steam and hot water are available Turning Economy Mode On and Off 1 The S1 must be in ON mode not Standby for all operations below 2 Press the Boiler button for 10 seconds until the ECON lamp illu...

Page 12: ...as an indication of when to turn off the pump and allow the 3 way valve to operate 4 2 Damaged GroupTemperature Probe This alarm is a blocking one and occurs when the temperature probe of the group i...

Page 13: ...er without the controller circuit receiving a boiler full signal this alarm is triggered This alarm can be temporarily cancelled by pressing the BOILER 26 button to turn off the boiler The S1 can be o...

Page 14: ...S1 Owner s Manual Page 12 5 Connection Diagrams 5 1 Electrical Connection Diagram...

Page 15: ...h between 15A and 20A mode J3 Jumpered 15A No Jumper 20A Newer S1 have the above board enclosed in a plastic case with a switch on the case used to change modes 5 3 Triac Board ConnectionDiagram BOILE...

Page 16: ...ing element SER 1 Connection control panel on control board SER 2 Connection control board on control panel F Flow meter Flin Phase inlet into the triac that feeds the boiler heating element Flout Pha...

Page 17: ...S1 Owner s Manual Page 15 6 S1 Water Flow Diagram The information below is provided strictly as a reference for S1 owners who are curious about the function of their S1 Dual Boiler design...

Page 18: ...the 3 way valve rarely if ever needs a detergent cleaning With the S1 on and fully heated use the included key wrench to remove the shower screen bolt Drop out the two screens and the dispersion disk...

Page 19: ...sen the lock nut 14mm wrench Press the One Cup 24 or Two Cup 25 button and wait for the gauge pressure to stabilize Most users prefer group pressure in the range 8 2 9 0 bar Turning the adjuster nut 1...

Page 20: ...If no water is dripping or running from the tube below nut C at 12 5 bar the expansion valve is set too high Use the 21mm socket to loosen nut C rotate counter clockwise as viewed from the bottom of t...

Page 21: ...on valve 3 The term expansion valve is somewhat of a misnomer as this device is really the overpressure valve for the group boiler The steam boiler has its own dedicated valve 8 Other LaSpaziale S1 Re...

Page 22: ...S1 Owner s Manual Page 20 9 Quick Setting Guide...

Reviews: