background image

 

 

S1 Owner’s Manual 

Page 6 

previously been programmed.) 

3.  To increase the temperature, press the 

BOILER 

(13) button.  The first press 

lights the yellow lamp over 

110 

(19)

 

which ind1°C.  A 2

nd

 press also lights 

the red lamp over 

120 

(20)

 

which ind2°C.  A 3

rd

 press also lights the red 

lamp over 

ECON 

(21)

 

which ind3°C.  A 4

th

 press of the 

BOILER 

(13) 

button extinguishes all three lamps indicating that the machine has cycled back 
to 0°C offset from the master setting. 

4.  To decrease the temperature, press the 

One Cup 

(23) button.  The first press 

lights the green lamp over 

95 

(16)

 

which indicates -1°C.  A 2

nd

 press also lights 

the green lamp over 

90 

(15)

 

which indicates  

-2°C.  A 3

rd

 press also lights the green lamp over 

85 

(14)

 

which indicates -3°C.  A 

4

th

  press of the 

One Cup 

(24) button extinguishes all three green lamps 

indicating that the machine has cycled back to 0°C offset from the master setting. 

5.  When finished, press the 

Two Cup 

(25) button until the lamps extinguish.  You 

will be back in Standby mode with only the 

ON/STBY 

(22)

 

lamp blinking.  At this 

time, your setting is memorized and will remain until you repeat the above 
procedure to change it. 

 

If, for example, your master temperature setting before entering the fine temperature 
control mode is 95°C and you press the 

One Cup 

(24) button until all three green lamps 

are lit, the water temperature is programmed to 92°C.  When back in normal operational 
mode with the green 95°C lamp lit steadily, the water temperature will actually be 92°C. 

 

NOTE: The master temperature setting and the fine temperature setting are 
completely independent. If you have set the temperature to 92°C, as in the above 
example, and later decide you want the temperature to be 100°C, changing the 
master setting to 100°C will result in 97°C water temperature because the fine 
temperature setting is still at -3°C. 

3.5  Espresso Brewing 

1.  Unfasten the portafilter handle (11) from the brewing group (10) and insert the filter 

for one or two cups. 

2.  Fill it with ground coffee, making sure not to leave coffee powder on the upper edge 

of the portafilter handle (11), and press it with the suitable coffee tamper provided. 

3.  Firmly attach the portafilter handle (11) to the brewing group (10). 

4.  Place one or two cups under the portafilter handle (11). 

5.  Press the button corresponding to one cup (24) if  you want to make one coffee or 

two cups (25) to start the delivery.  Once the desired quantity of coffee programmed 
is reached, the delivery automatically stops. 

Summary of Contents for S1 Vivaldi

Page 1: ...La Spaziale S1 Vivaldi Double Boiler Espresso Machine Owner s Manual Last Updated on 03 31 2014...

Page 2: ...4 1 Damaged Flow Meter 10 4 2 Damaged Group Temperature Probe 10 4 3 Damaged Boiler Temperature Probe 10 4 4 Damaged Group Heating Element Triac 10 4 5 Damaged Boiler Heating Element Triac 10 4 6 Boi...

Page 3: ...in Safety Thermostat Semi Automatic Hot Water Delivery Manual Steam Valve Fault Diagnosis Alarms Boiler Pressure Gauge Two Complete Portafilter handles Single and Double Baskets Extra shower screens...

Page 4: ...ontrol Panel 16 95 C Lamp 23 Hot Water Button 3 Rubber Feet 10 Group 17 100 C Lamp 24 One Cup Button 4 Boiler Pressure 11 Portafilter Handle 18 105 C Lamp 25 Two Cup Button 5 Side Panels 12 Drip Tray...

Page 5: ...ecedence and then the steam boiler operates in sequential fashion A number of 15A S1 owners note that they see little operational effect when running in this mode The 20A S1 allows both boilers to ope...

Page 6: ...adily for about a second indicating power on test mode 3 The light corresponding to the set temperature starts flashing to indicate that the group is heating and the automatic boiler refill starts unt...

Page 7: ...u choose the desired temperature in order to lock in this value press the ON OFF 27 button the machine will then go back to its normal functioning The value of the operating temperature of the machine...

Page 8: ...e to change it If for example your master temperature setting before entering the fine temperature control mode is 95 C and you press the One Cup 24 button until all three green lamps are lit the wate...

Page 9: ...handle and press it with the included plastic tamper or more optimally a high quality 53mm coffee tamper 3 Fasten the portafilter handle 11 to the brewing group l0 placing a cup under the portafilter...

Page 10: ...eam boiler on and off 2 Entry and exit of Economy mode There are three possible operational modes of the two boilers in the La Spaziale S1 20A model 1 Both boilers are completely independent turning o...

Page 11: ...ing Steam and hot water are available Turning Economy Mode On and Off 1 The S1 must be in ON mode not Standby for all operations below 2 Press the Boiler button for 10 seconds until the ECON lamp illu...

Page 12: ...as an indication of when to turn off the pump and allow the 3 way valve to operate 4 2 Damaged GroupTemperature Probe This alarm is a blocking one and occurs when the temperature probe of the group i...

Page 13: ...er without the controller circuit receiving a boiler full signal this alarm is triggered This alarm can be temporarily cancelled by pressing the BOILER 26 button to turn off the boiler The S1 can be o...

Page 14: ...S1 Owner s Manual Page 12 5 Connection Diagrams 5 1 Electrical Connection Diagram...

Page 15: ...h between 15A and 20A mode J3 Jumpered 15A No Jumper 20A Newer S1 have the above board enclosed in a plastic case with a switch on the case used to change modes 5 3 Triac Board ConnectionDiagram BOILE...

Page 16: ...ing element SER 1 Connection control panel on control board SER 2 Connection control board on control panel F Flow meter Flin Phase inlet into the triac that feeds the boiler heating element Flout Pha...

Page 17: ...S1 Owner s Manual Page 15 6 S1 Water Flow Diagram The information below is provided strictly as a reference for S1 owners who are curious about the function of their S1 Dual Boiler design...

Page 18: ...the 3 way valve rarely if ever needs a detergent cleaning With the S1 on and fully heated use the included key wrench to remove the shower screen bolt Drop out the two screens and the dispersion disk...

Page 19: ...sen the lock nut 14mm wrench Press the One Cup 24 or Two Cup 25 button and wait for the gauge pressure to stabilize Most users prefer group pressure in the range 8 2 9 0 bar Turning the adjuster nut 1...

Page 20: ...If no water is dripping or running from the tube below nut C at 12 5 bar the expansion valve is set too high Use the 21mm socket to loosen nut C rotate counter clockwise as viewed from the bottom of t...

Page 21: ...on valve 3 The term expansion valve is somewhat of a misnomer as this device is really the overpressure valve for the group boiler The steam boiler has its own dedicated valve 8 Other LaSpaziale S1 Re...

Page 22: ...S1 Owner s Manual Page 20 9 Quick Setting Guide...