Adjustments and Maintenance 

7.1  External S1 Surface Cleaning 

Use a damp sponge and wipe dry with a soft cloth.  Alternately, window cleaner wiped 
off with a dry soft cloth works well. 

7.2  Routine Group Cleaning 

The extra pair of shower screens was not included with your S1 so you'd have an extra 
set.  

They are included as part of LaSpaziale’s recommended cleaning regimen which is 

targeted at light commercial use where there is no time for a complete detergent based 
back flush routine.  

The reason for LaSpaziale’s double shower screen arrangement is 

to trap grounds between the screens so that the 3-way valve rarely, if ever, needs a 
detergent cleaning.

 

 

With the S1 on and fully heated, use the included key wrench to remove the 
shower screen bolt.

 

 

Drop out the two screens and the dispersion disk.

 

 

Use the included plastic handled wire brush to quickly scrub the group head 
while water is running through the group to flush out the particles. (This is why 
the long handled brush - to keep your hands away from hot water.)

 

 

Also, give the dispersion disk a quick scrub.

 

 

Reassemble using the other set of screens.

 

 

Soak the original set of screens in Cafiza or similar detergent, scrub, rinse, and 
put away for next time.

 

 

 

NOTE: The following are advanced maintenance and 
adjustment procedures.  Do not perform them without the 
proper tools and confidence that you can do them properly. 
When in doubt always contact your S1 vendor first.

 

Summary of Contents for S1 Vivaldi

Page 1: ...La Spaziale S1 Vivaldi Double Boiler Espresso Machine Owner s Manual Last Updated on 03 31 2014...

Page 2: ...4 1 Damaged Flow Meter 10 4 2 Damaged Group Temperature Probe 10 4 3 Damaged Boiler Temperature Probe 10 4 4 Damaged Group Heating Element Triac 10 4 5 Damaged Boiler Heating Element Triac 10 4 6 Boi...

Page 3: ...in Safety Thermostat Semi Automatic Hot Water Delivery Manual Steam Valve Fault Diagnosis Alarms Boiler Pressure Gauge Two Complete Portafilter handles Single and Double Baskets Extra shower screens...

Page 4: ...ontrol Panel 16 95 C Lamp 23 Hot Water Button 3 Rubber Feet 10 Group 17 100 C Lamp 24 One Cup Button 4 Boiler Pressure 11 Portafilter Handle 18 105 C Lamp 25 Two Cup Button 5 Side Panels 12 Drip Tray...

Page 5: ...ecedence and then the steam boiler operates in sequential fashion A number of 15A S1 owners note that they see little operational effect when running in this mode The 20A S1 allows both boilers to ope...

Page 6: ...adily for about a second indicating power on test mode 3 The light corresponding to the set temperature starts flashing to indicate that the group is heating and the automatic boiler refill starts unt...

Page 7: ...u choose the desired temperature in order to lock in this value press the ON OFF 27 button the machine will then go back to its normal functioning The value of the operating temperature of the machine...

Page 8: ...e to change it If for example your master temperature setting before entering the fine temperature control mode is 95 C and you press the One Cup 24 button until all three green lamps are lit the wate...

Page 9: ...handle and press it with the included plastic tamper or more optimally a high quality 53mm coffee tamper 3 Fasten the portafilter handle 11 to the brewing group l0 placing a cup under the portafilter...

Page 10: ...eam boiler on and off 2 Entry and exit of Economy mode There are three possible operational modes of the two boilers in the La Spaziale S1 20A model 1 Both boilers are completely independent turning o...

Page 11: ...ing Steam and hot water are available Turning Economy Mode On and Off 1 The S1 must be in ON mode not Standby for all operations below 2 Press the Boiler button for 10 seconds until the ECON lamp illu...

Page 12: ...as an indication of when to turn off the pump and allow the 3 way valve to operate 4 2 Damaged GroupTemperature Probe This alarm is a blocking one and occurs when the temperature probe of the group i...

Page 13: ...er without the controller circuit receiving a boiler full signal this alarm is triggered This alarm can be temporarily cancelled by pressing the BOILER 26 button to turn off the boiler The S1 can be o...

Page 14: ...S1 Owner s Manual Page 12 5 Connection Diagrams 5 1 Electrical Connection Diagram...

Page 15: ...h between 15A and 20A mode J3 Jumpered 15A No Jumper 20A Newer S1 have the above board enclosed in a plastic case with a switch on the case used to change modes 5 3 Triac Board ConnectionDiagram BOILE...

Page 16: ...ing element SER 1 Connection control panel on control board SER 2 Connection control board on control panel F Flow meter Flin Phase inlet into the triac that feeds the boiler heating element Flout Pha...

Page 17: ...S1 Owner s Manual Page 15 6 S1 Water Flow Diagram The information below is provided strictly as a reference for S1 owners who are curious about the function of their S1 Dual Boiler design...

Page 18: ...the 3 way valve rarely if ever needs a detergent cleaning With the S1 on and fully heated use the included key wrench to remove the shower screen bolt Drop out the two screens and the dispersion disk...

Page 19: ...sen the lock nut 14mm wrench Press the One Cup 24 or Two Cup 25 button and wait for the gauge pressure to stabilize Most users prefer group pressure in the range 8 2 9 0 bar Turning the adjuster nut 1...

Page 20: ...If no water is dripping or running from the tube below nut C at 12 5 bar the expansion valve is set too high Use the 21mm socket to loosen nut C rotate counter clockwise as viewed from the bottom of t...

Page 21: ...on valve 3 The term expansion valve is somewhat of a misnomer as this device is really the overpressure valve for the group boiler The steam boiler has its own dedicated valve 8 Other LaSpaziale S1 Re...