![LA NORDICA Focolare 80 Idro Crystal DSA Instructions For Installation, Use And Maintenance Manual Download Page 25](http://html1.mh-extra.com/html/la-nordica/focolare-80-idro-crystal-dsa/focolare-80-idro-crystal-dsa_instructions-for-installation-use-and-maintenance-manual_666871025.webp)
Focolare 80 Idro Crystal - DSA
6097811 Rev.06 – EN
25
6.
CONNECTION TO THE FLUE
The connection to the flue (exhaust channel or pipe fitting) must be made using rigid pipes in aluminium plated steel
with minimum thickness of 2 mm or in 316 stainless steel with minimum thickness of 1 mm.
It is prohibited to use flexible metal pipes or asbestos cement pipes because they are subject to splitting or
breakage, which can lead to fume leakage, jeopardising the safety of the connection itself.
The diameter of opening for the connection to the connection of chimney must correspond to the smoke pipe diameter
at least. The opening should have a connection to the wall to put inside the outlet pipe and a rose window.
Picture 10
Picture 11
Picture 12
CHIMNEY CAP: DISTANCES AND POSITIONING UNI 10683/98
Roof slope
Distance between roof ridge and
chimney
Minimum height of chimney
(measured from the outlet )
A (m)
H (m)
15°
< 1,85 m
0.50 m above the ridge
> 1,85 m
1.00 m from roof
30°
< 1,50 m
0.50 m above the ridge
> 1,50 m
1.30 m from roof
45°
< 1,30 m
0.50 m above the ridge
> 1,30 m
2.00 m from roof
60°
< 1,20 m
0.50 m above the ridge
> 1,20 m
2.60 m from roof
50 cm
(1) In the case of adjacent flues, one chimney cap must rise above
the other by at least 50 cm to prevent the transfer of pressure
between the flues.
(1) The chimney cap must not have any obstacles within 10 m from
walls, pitch, and trees. In such case, it must be raised at least 1 m
above the obstacles.
The chimney cap must rise above the roof ridge by at least 1 m.
2 m
10 m
1
m
>
_
A
>A
0.5 m
min. H
(2)Roof
(1)Ridge axis
colmo