background image

8

EN

MODELS “EE” “AV” and “PADDLE”

1, 2, 3 and 4 groups 

1) Accessories

Check the package to make sure that the

following accessories are included:

• a  number  of  1-dose  and  2-dose

portafilters  according  to  the  number

of groups;

• replacement  1-dose  and  2-dose  filter

baskets

• 1 tamper

• 1 blind filter

• cleaning detergent, for the groups

• 3  stainless  steel  braided  hoses  for

water connections

• 1,5 mt of reinforced plastic tubing for

drainage

• 1 hose clamp

In order to proceed with installation, it is 

necessary that the following are available:

• Pipes  carrying  drinking  water  with  a

3/8”G  (BSP)  end  connection;  (3/8”

Compression for USA and Canada)

• Electrical  Supply  according  to  the

specification of the espresso machine

purchased  (not  all  specifications  are

available in all markets):

→  Single/Three  phase  220VAC  -  50/60 

Hz  electrical  connection  with  ground, 

protected receptacle and approved circuit 

breaker

→  Single phase 200VAC - 50/60 Hz electrical 

connection  with  ground,  protected 

receptacle and approved circuit breaker

→  Three-phase, 380VAC - 50/60 Hz electrical 

connection with n ground, near the 

bench  on  which  the  machine  is  installed 

and  terminating  in  a  suitable  protected 

fivepole  receptacle  equipped  with  an 

approved  circuit breaker

• Waste water drain system

Note:

• The  drinking  water  mains  valve  and

the  circuit  breakers  for  the  electrical

system need to be located in the most

convenient position for the operator to

access them easily and quickly.

• The machine should be placed on a flat

counter and must be placed in settings

with the following temperatures:

Minimum room temperature: 5°C/41°F

Maximum room temperature: 32°C/89°F

• If  the  machine  has  been  temporarily

housed  in  settings  with  a  room

temperature  of  less  than  0°C/32°F,

please  contact  a  service  technician

prior to use.

• Water  pressure  supply  must  be

between 2 and 6 bar.

2) Water supply connection

In  order  to  connect  the  machine  up  to

the  water  mains  proceed  according  to

the indications given in the chapter about

Installation  and  in  compliance  with  any

local/national  safety  standards  of  the

location  in  which  the  machine  is  being

installed.

To  guarantee  a  correct  and  safe

functioning  of  the  machine  and  to

maintain  an  adequate  performance  level

and a high quality of the beverages being

brewed it is important that the incoming

water  be  of  a  hardness  greater  than  9°f

(90ppm, 5°d) and less than 15°f (150ppm,

8.4°d), pH should be between 6.5 and 8.5

and the quantity of chlorides be less than

50mg/l .  Respecting these values allows

the  machine  to  operate  at  maximum

efficiency.  If  these  parameters  are  not

present, a specific filtration device should

be installed, while always adhering to the

local national standards in place regarding

potable water.

Then connect the inlet of the water filter/

softener (if present) to the drinking water

supply using one of the supplied stainless

steel  braided  hoses.    Before  connecting

the  filter  to  the  water  pump,  flush  the

WARNING

AT EACH INSTALLATION, THE MACHINE 

SHOULD BE EqUIPPED WITH A NEW SET OF 

TUBES FOR PLUMBING AND RELATED

GASKETS.

WARNING

HAZARDOUS VOLTAGE DISCONNECT FROM 

POWER SUPPLY BEFORE SERVICING

Summary of Contents for Linea

Page 1: ...ne the industry The Linea is the classic La Marzocco machine that has long supported and helped to develop the specialty coffee industry since the 1990s It is a heavy duty workhorse that performs reli...

Page 2: ...39 055 849 1990 page 2 page 4 page 7 page 11 page 16 page 18 page 19 page 21 page 22 1 General Warnings and Safety Specifications 2 Definition of Available Models 3 Installation 4 Machine Operation a...

Page 3: ...nit very carefully Make sure grounding has been done correctly as it represents a fundamental safety requirement and in case of doubt do not hesitate to have qualified personnel check such connection...

Page 4: ...the cup warmer tray with cloths or other items 13 The machine s power supply cable must not be replaced by users as also specified on the rating plate located near the outlet of such cable on the bod...

Page 5: ...ig 2 Front panel of PADDLE model available with 1 2 3 and 4 groups 1 Main Switch 2 Water level sight glass 3 Pressure gauge 4 Coffee groups 5 Coffee brewing control switch 6 Cup warmer switch non UL m...

Page 6: ...3groups 5 0litres 1600or1900Watts 4groups 3 4 3 4litres 1400 1400Watts 2boilersinstalled It consists of a cylindrical tank of varying length according to the number of coffee groups which is made of s...

Page 7: ...quantity of water for one normal espresso coffee a quantity of water for one tall coffee a quantity of water for two normal coffees a quantity of water for two tall coffees The fifth button is used t...

Page 8: ...nsion valve 20 Group cover 21 Bleed screw 22 PID Temperature Controller 23 Switch not provided 24 Plug not provided 25 Connectors Fig 4 THE COFFEE MACHINE MUST BE PLACED IN A HORIZONTAL POSITION ON A...

Page 9: ...ould be placed on a flat counter and must be placed in settings with the following temperatures Minimum room temperature 5 C 41 F Maximum room temperature 32 C 89 F If the machine has been temporarily...

Page 10: ...ter pump motor power cord This is the power supply for the water pump motor The internal electronics will switch the pump motor on when needed 3 core cable with 1 5 mm2 cross section or 3 core AWG 16...

Page 11: ...l be necessary in order to completely saturate the boiler groups assembly to remove the group cover plate part 20 Fig 4 and unscrew the small bolt part 21 called bleed screws a little way so as to all...

Page 12: ...he first installation procedures are finished before proceeding with brewing coffee hot water and steam please follow these steps Engage the portafilters by inserting them into each group brew water t...

Page 13: ...d valve diffuser diffuser coffee brewing spout The wheel is designed in such a way as to rotate freely when water is flowing by it sends 2 signals every complete rotation to the electronic module whic...

Page 14: ...ater flow within the factory set time of the electronic module 2 insufficient water flow through the groups i e onto the coffee powder probably due to a combination of one or more of the following occ...

Page 15: ...ting elements in order to bring the water contained in such boiler up to operating temperature However in this case it is necessary to adjust the expansion valve marked 19A in fig 4 in such a way that...

Page 16: ...value or SV setting value When set ting a parameter its name or its value appears 3 SEL key Used to switch the PV display to from the SV display and select a parameter block and a parameter and regis...

Page 17: ...e press to decrease the value by 1 Press and hold this key to decrease to desired value then wait a few seconds to automatically exit programming function For more detailed information on the potentia...

Page 18: ...u will end up with a fresh cappuccino In order to prevent part of the liquid to be heated from being sucked back into the boiler due to a possible temporary decompression inside the boiler tank which...

Page 19: ...drain collector Remove the drain tray grill every night pull out the water drain collector and clean it thoroughly Also inspect and clean the drain well part 19 at least twice a week and remove any l...

Page 20: ...lve part 19A should start working by discharging a few drops of water in order to prevent such pressure from exceeding 12 bar If the pressure exceeds 12 bar you must adjust the valve by unscrewing the...

Page 21: ...sed in advance Proceed to remove the drain well piping part 19 At this point the machine may be removed from the bar being very careful not to drop it The machine is made out of various mate rials and...

Page 22: ...tallation otherwise warranty is voided If AV Model Check shot volumes Test flowmeter s ohm value ohm value is acceptable if greater than 1 8 K ohm and less than 2 2 K ohm If MP Model Rebuild MP valve...

Page 23: ...EN...

Reviews: