![La Marzocco GB/5 Manual Download Page 7](http://html2.mh-extra.com/html/la-marzocco/gb-5/gb-5_manual_3117385007.webp)
EN
6
3. Installation
8000
35
2800
5000
8000
3/5 WIRES x 10mm²
3 X WIRES
220V
THE DETAILS ON THE LEFT DESCRIBE
HOW TO CONNECT EACH WIRE TO THE PLUG.
RESPECT ALSO THE LOCAL SAFETY
REGULATIONS.
MODEL/SERIES
GROUP
V/Hz
RATED
POWER
(W)
RATED
INPUT (A)
COFFEE
BOILER
WATTAGE
STEAM
BOILER
WATTAGE
TOTAL
WATTAGE
POWER CORD
SIZE (mm²)
GB/5
2GR
4600
21
1400
3000
4600
3/5 WIRES x 4mm²
FB/80
2GR
4600
21
1400
3000
4600
3/5 WIRES x 4mm²
GB/5
3GR
6100
28
1900
4000
6100
3/5 WIRES x 6mm²
FB/80
3GR
6100
28
1900
4000
6100
3/5 WIRES x 6mm²
GB/5
4GR
8000
35
2800
5000
8000
3/5 WIRES x 10mm²
FB/80
4GR
POWER CORD:
1 X BLUE (NEUTRAL)
1 X BROWN (PHASE)
1 X YELLOW & GREEN (GROUND)
5 X WIRES
380V
1 X BROWN (PHASE)
1 X GRAY (PHASE)
1 X BLACK (PHASE)
1 X BLUE (NEUTRAL)
1 X YELLOW & GREEN (GROUND)
AC220V/50-60Hz
AC208V-240V/50-60Hz
AC380V/50-60Hz
AC220V/50-60Hz
AC208V-240V/50-60Hz
AC380V/50-60Hz
AC220V/50-60Hz
AC208V-240V/50-60Hz
AC380V/50-60Hz
AC220V/50-60Hz
AC208V-240V/50-60Hz
AC380V/50-60Hz
AC220V/50-60Hz
AC208V-240V/50-60Hz
AC380V/50-60Hz
AC220V/50-60Hz
AC208V-240V/50-60Hz
AC380V/50-60Hz
(not provided)
(not provided)
Water
Mains
Valve
X
Water Hose
Underneath Base of the Frame
Fig. 3 - Installation Nomenclature
Fig. 2 - Installation Guide
Drain Hose Connection
Expansion Valve
Drain Grate
Drain Tray
WARNING
THIS APPLIANCE IS NOT INTENDED FOR USE BY
PERSONS (INCLUDING CHILDREN) WITH REDUCED
PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR WITH LACK OF EXPERIENCE AND KNOWLEDGE,
UNLESS THEY HAVE BEEN GIVEN SUPERVISION
OR INSTRUCTION CONCERNING THE USE OF THE
APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR
SAFETY.
WARNING
THE COFFEE BOILER AND STEAM BOILER CONTAIN
WATER AT ELEVATED TEMPERATURE. WATER
TEMPERATURE OVER 125°F / 52°C CAN CAUSE SEVERE
BURNS INSTANTLY OR DEATH FROM SCALDING (COFFEE
BOILER 207°F/97°C-STEAM BOILER 256°F /124°C)