EN
41
Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
1
L a Ma r z o c c o 0 9: 3 0
2
3
4
5
Press and hold the
button on the group 1 keypad until the following is displayed (approximately 10
seconds)
Enter the 5 digit technician password using buttons 1-5 on the group 1 keypad. Once accepted the following
appears:
Press the
button on the group 1 keypad until the following appears:
Press the
or the
button to change to with pump or without pump. Once the desired condition is
displayed press the
to conirm.
When inished, continue to the next parameter
or press
to exit programming mode.
• This parameter allows the technician to
select the activation of the water pump
during the steam boiler auto- ill cycle.
• Only under unusual circumstances would
the option of “without pump” be chosen.
• The electronics installed in this espresso
machine give priority to the brew boiler
for pressure. The activation of the auto-
ill cycle during the brewing process can
reduce the overall dispensing pressure in
the brew boiler.
• During the auto-ill cycle, if a brew cycle
is chosen, the auto-ill cycle is delayed
until all brew cycles are complete.
Steam Boiler Automatic Fill
Fi l l i ng - u p
wi t h pu mp
Pa s s wo r d
? ? ? ? ?
La n g u a g e
ENGLI SH
Fi l l i n g - u p
wi t h p u mp