background image

 

15

3) Be sure the radio-controlled clock is at 

least 6 feet (2 meters) from any 
electrical devices, i.e. TV sets, 
computers, or other radio controlled 
clocks. 

4) Remove batteries for five minutes, 

reinsert and leave the unit alone 
overnight without pressing any keys. 

Problem: 

Hour is incorrect (minute and date are 
correct). 

Solution: 

1) Be sure the correct time zone and 

daylight saving time is selected. 

Problem: 

"OFL“ appears in the indoor 
temperature section of the LCD 

Solution: 

1) Move the radio-controlled clock to an 

area with warmer or cooler 
surrounding temperature. Current 
surrounding temperatures are 
outside measuring range. Batteries. 

Problem: 

"00" appears in the in humidity section 
of the LCD. 

Solution: 

1) Remove the battery from the unit for 

ten minutes,

 

Press any button 20 

times with battery out

 

then reinsert it 

again.   

Problem:

 

The clock appears to be locked up or 

displays partial segments.

 

Solution:

 

Remove the battery, slide the battery 

switch to BATTERY and reinsert 
the the battery.  

If you are using a rechargeable 

battery, you can then slide the 
battery switch to SOLAR. 

 

CARE AND MAINTENANCE: 

 

Avoid placing the unit in areas prone to vibration and 
shock as these may cause damage. 

 

16

 

Avoid areas where the unit can be exposed to sudden 
changes in temperature, i.e. direct sunlight, extreme cold 
and wet/moist conditions as these will lead to rapid 
changes which reduce the accuracy of readings. 

 

When cleaning the LCD and casing, use a soft damp 
cloth only. Do not use solvents or scouring agents. 

 

Do not submerge the unit into water. 

 

Immediately remove all low powered batteries to avoid 
leakage and damage. Replace only with new battery of 
the recommended size. 

 

Do not make any repairs to the unit. Please return it to 
the original point of purchase. Opening and tampering 
with the unit may invalidate the warranty. 

SPECIFICATIONS: 

 

Temperature measuring range 

 

 

Indoor 

:    14.1

F to 139.8

F with 0.2

F resolution (-9.9

C to 

+59.9

C with 0.1

C resolution; “OFL” displayed if 

outside this range) 

 

Temperature checking interval 

 

 

Indoor 

:    every 60 seconds 

 

Humidity measuring range

 

Indoor   :  20% to 95% with 1% resolution 

 

 

 

(“—“ displayed if temperature is OFL; “19%” 
displayed if below 20%, “96%” displayed if above 
95%) 

 

Temperature checking interval 

Indoor   :  every 60 seconds

 

 

Power consumption 

Alkaline rechargeable Battery   :    
1 x AA, 1.5V (included), rechargeable by solar cell  
Rechargeable Alkaline battery life :    
18 – 60 months, depending on usage 
Primary Alkaline battery 

:     

1 x AA, 1.5V battery (not included) 
Primary Alkaline battery life :    about 24 months 

 

Dimensions (H x L x W)

 

 

Solar clock 

:  8.93“ x 1.18“ x 7.16“ / 227 x 30 x 182mm 

Summary of Contents for WT-8029U

Page 1: ...y cover Wall Mount Location LCD2 display Foldable stands Solar panel TABLE OF CONTENTS Topic Page Features 3 Battery Installation 3 Setting Up 5 Atomic time WWVB Radio Controlled Time 5 Function keys...

Page 2: ...Changing Installing the Battery 4 TO INSTALL REPLACE BATTERY The included alkaline rechargeable battery should provide you with many years of service If your battery needs to be replaced we suggest y...

Page 3: ...nected with WWVB it will override the manually set time and date Note When changing the battery 1 Be careful that it does not spring free from the contacts 2 Press any button 20 times with the battery...

Page 4: ...guage hour minute year month date weekday 12 24h time format display F C temperature unit and solar mode key To change any values in manual set mode ALM key To enter into the alarm set mode To activat...

Page 5: ...does receive the signal it will change the manually set time into the received time During reception attempts the WWVB tower icon will flash If reception has been unsuccessful then the WWVB tower ico...

Page 6: ...ss and release the SET key to enter the mode Solar Mode Setting 12 SOLAR MODE The Solar Mode is used for saving the power consumption of the rechargeable battery Default setting ON 1 The characters ON...

Page 7: ...ta There are two possible ways to mount the solar clock use of the foldable table stands or wall mounting Alarm icon ON 14 FOLDABLE TABLE STANDS The foldable table stands legs are located on the backs...

Page 8: ...Avoid areas where the unit can be exposed to sudden changes in temperature i e direct sunlight extreme cold and wet moist conditions as these will lead to rapid changes which reduce the accuracy of r...

Page 9: ...ding the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deterioration of any accessory or decorative surface 4 d...

Reviews: