background image

10

 

 

 

LEARNING/ REMOVING A REMOTE TEMPERATURE/HUMIDITY SENSOR (CHANNEL) 
 

After replacement of batteries of a particular remote temperature/humidity sensor, it is necessary to learn the remote 
temperature/humidity sensor again in the learning mode. On the other hand, when a user wants to decrease the number 
of remote temperature/humidity sensors to be applied, they may remove the remote temperature/humidity sensors so that 
the data from this channel will not be displayed in the indoor weather station. The below procedures describe how to “re-
learn” or “remove” a channel: 
 
1. 

Press and hold the SET key until the digits “Lcd” starts flashing. 

2. 

Press shortly the SET key eleven times to enter Learn/ Remove setting of channels. The digits “Lrn”, “CH” and the 
channel icons will be flashing. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
3. 

Press Plus to select Channel 1. The digit ”1” will be flashing. 

4. 

Press Plus to set Channel 1 to “Re-learn” state (The channel icon will be flashing), or press Minus to remove 
Channel 1 (The channel icon will disappear). 

5. 

Press SET key to select Channel 2. The digit “2” will be flashing. 

6. 

Repeat the above steps to Channel 2 to 3, setting them either in “re-learnt” or “removed” state.    

 
Note:

  Once a channel is removed, the indoor weather station will be “disconnected” from the channel and the data 

transmitted by this channel cannot be viewed at the indoor weather station.    

 

THE NUMBER OF REMOTE TEMPERATURE/HUMIDITY SENSOR TO BE SAVED INTO THE SYSTEM MEMORY  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
Up to 3 remote temperature/humidity sensors can be received by the indoor weather station. The user may decide the 
number of remote temperature/humidity sensor data to be saved to the permanent memory of the indoor weather station. 
For instant, user may apply 3 remote temperature/humidity sensors but set to save the data only from 2 particular remote 
temperature/humidity sensors. To set the number of remote temperature/humidity sensor s whose data are to be saved in 
the system memory: 
 
1. 

Press and hold the SET key until the digits “Lcd” starts flashing. 

2. 

Press and release the SET key twelve times to enter remote temperature/humidity sensor number setting. The digit 
“Enr” will be flashing.  

3. 

Use the Plus and Minus key to select the number of remote temperature/humidity sensor to be used with the 
weather station (up to 3 transmitters) 

4. 

Press the SET key one more time to confirm and go back to the normal display mode. 

 

Digit flashing 

 

Flashing

Digits flashing 

Summary of Contents for WS-8610U

Page 1: ...time of reception Indoor and outdoor humidity display as RH with MIN MAX records Data logging function can store up to 3000 sets of temperature humidity data Connectable to PC Com port data can be tra...

Page 2: ...es working error may result Note After changing the batteries in the indoor weather station there is no need for user to reset the indoor weather station In fact the indoor weather station can remembe...

Page 3: ...After the batteries have been installed the indoor weather station will search for the signal for a duration of 5 minutes If there is no temperature or humidity reading in the OUTDOOR LCD after 5 minu...

Page 4: ...justment increase or decrease in different manual settings and alarm setting Mode key MODE In normal display mode press to toggle between the following view mode a Maximum record of a selected channel...

Page 5: ...de for the following a LCD contrast setting b Time zone setting c Daylight saving time on off setting d Radio controlled time reception on off setting e 12 24 hour format setting f Time setting Hour a...

Page 6: ...he mode or Alarm AL key to go back to the normal display mode TIME ZONE SETTING The time zone default of the weather station is 0 To set a different time zone 1 Press and hold the SET key until the di...

Page 7: ...splay mode TIME RECEPTION ON OFF SETTING In areas where reception of the WWVB time signal is not possible the WWVB time reception function can be turned OFF The clock will then work as a normal Quartz...

Page 8: ...ld the SET key until the digits Lcd starts flashing 2 Press and release the SET key five times to enter the hour setting The hour digit in the time LCD will be flashing 3 Use the Plus and Minus key to...

Page 9: ...will be flashing 5 Use the Plus and Minus key to set the month 6 Press the SET key one more time to confirm the month and advance to the day setting The day digit will be flashing 7 Use the Plus and...

Page 10: ...to 3 setting them either in re learnt or removed state Note Once a channel is removed the indoor weather station will be disconnected from the channel and the data transmitted by this channel cannot...

Page 11: ...ELS INDOOR AND OUTDOOR CHANNELS 1 Press the Plus or Minus key to toggle between the temperature and humidity readings of the indoor channel and the remote temperature humidity sensor channel s The cha...

Page 12: ...the data which have been saved in the system memory will be displayed The avg icon will be flashing If the remote temperature humidity sensor channel is not set to be saved in the system memory no av...

Page 13: ...t at 85 F and 65 F respectively Then the alarm will sound once the temperature is higher than 85 F or lower than 65 F To set the high humidity alarm 1 In normal display press the Plus or Minus key to...

Page 14: ...e Alarm key to enter the high temperature alarm setting To set the high temperature alarm 1 In normal display press the Plus or Minus key to select a temperature humidity sensor the temperature humidi...

Page 15: ...nd 65 F low while only activating high temp alarm and deactivating low temp alarm In this case the alarm will not trigger when temperature is lower than 65 F yet will trigger when temp is higher than...

Page 16: ...ond The maximum and minimum temperature humidity data and the time of record will be reset to the current value CLEARING THE MAX MIN TEMPERATURE AND HUMIDITY DATA OF ALL REMOTE TEMPERATURE HUMIDITY SE...

Page 17: ...minutes followed by the full segment display You are then required to remove and re insert the batteries to complete the restart of the unit After batteries are re inserted the station will automatica...

Page 18: ...ck the following items 1 The distance of the indoor weather station or remote temperature humidity sensors should be at least 6 feet 2 meters away from any interfering sources such as computer monitor...

Page 19: ...t over the desired location 3 Through the screw holes of the bracket mark the mounting surface with a pencil 4 Screw mounting bracket onto the mounting surface Ensure that the screws are flush with th...

Page 20: ...s to the units Return it to their original point of purchase for repair by a qualified engineer Opening and tampering with the units may invalidate their guarantee Do not expose the units to extreme a...

Page 21: ...n your owner s manual 5 damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology Ltd authorized service center 6 units used for other th...

Reviews: