e. 

The history data sets of temperature and humidity  

 
 
 
 
 
 
 
 
 
 
 
 
 
 

In normal display mode, press the mode key five times. The “hist” icon will be flashing and the last recorded 
temperature and humidity reading with the time of record will be displayed.  
By pressing the Minus key, the previous sets of readings which were measured at the user-selected recording 
intervals may be viewed.  
If the remote temperature/humidity sensor channel is not set to be saved in the system memory, no history values 
will be displayed and “--.-“ will be shown on LCD. 
 

ALARM PROGRAMMING FOR INDOOR/ OUTDOOR TEMPERATURE AND HUMIDITY 

 

The indoor weather station will allow users to set a range of specific alarms to meet specific temperature and humidity 
conditions set by the user. 
For example, user may set the high and low temperature alarm point at 85°F and 65°F respectively. Then the alarm will 
sound once the temperature is higher than 85°F or lower than 65°F. 

 
To set the high humidity alarm: 
 

1. 

In normal display, press the Plus or Minus key to select a temperature/humidity sensor channel (the 
temperature/humidity sensor at the indoor weather station or one of the remote temperature/humidity sensors). 

2. 

Press and hold the Alarm key for about 3 second to enter high humidity alarm setting. The humidity digits, high limit 
icon and the alarm icon will start flashing. 

3. 

Press the Mode key to select to “activate” or “deactivate” the high humidity alarm. (“Alarm On” icon displayed 
represents the alarm is on). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
4. 

Press the Plus or Minus key to set the desired value of the high humidity alarm threshold point. 

5. 

Press SET key to return to the normal display or press the Alarm key to enter the low humidity alarm setting. 

 
 
 
 
 
 
 

History data icon flashing 

Alarm On icon (If this icon does 
not show, the alarm is set to be 
off)  

High limit icon

Humidity digit 
flashing 

Summary of Contents for WS-8610U

Page 1: ...time of reception Indoor and outdoor humidity display as RH with MIN MAX records Data logging function can store up to 3000 sets of temperature humidity data Connectable to PC Com port data can be tra...

Page 2: ...es working error may result Note After changing the batteries in the indoor weather station there is no need for user to reset the indoor weather station In fact the indoor weather station can remembe...

Page 3: ...After the batteries have been installed the indoor weather station will search for the signal for a duration of 5 minutes If there is no temperature or humidity reading in the OUTDOOR LCD after 5 minu...

Page 4: ...justment increase or decrease in different manual settings and alarm setting Mode key MODE In normal display mode press to toggle between the following view mode a Maximum record of a selected channel...

Page 5: ...de for the following a LCD contrast setting b Time zone setting c Daylight saving time on off setting d Radio controlled time reception on off setting e 12 24 hour format setting f Time setting Hour a...

Page 6: ...he mode or Alarm AL key to go back to the normal display mode TIME ZONE SETTING The time zone default of the weather station is 0 To set a different time zone 1 Press and hold the SET key until the di...

Page 7: ...splay mode TIME RECEPTION ON OFF SETTING In areas where reception of the WWVB time signal is not possible the WWVB time reception function can be turned OFF The clock will then work as a normal Quartz...

Page 8: ...ld the SET key until the digits Lcd starts flashing 2 Press and release the SET key five times to enter the hour setting The hour digit in the time LCD will be flashing 3 Use the Plus and Minus key to...

Page 9: ...will be flashing 5 Use the Plus and Minus key to set the month 6 Press the SET key one more time to confirm the month and advance to the day setting The day digit will be flashing 7 Use the Plus and...

Page 10: ...to 3 setting them either in re learnt or removed state Note Once a channel is removed the indoor weather station will be disconnected from the channel and the data transmitted by this channel cannot...

Page 11: ...ELS INDOOR AND OUTDOOR CHANNELS 1 Press the Plus or Minus key to toggle between the temperature and humidity readings of the indoor channel and the remote temperature humidity sensor channel s The cha...

Page 12: ...the data which have been saved in the system memory will be displayed The avg icon will be flashing If the remote temperature humidity sensor channel is not set to be saved in the system memory no av...

Page 13: ...t at 85 F and 65 F respectively Then the alarm will sound once the temperature is higher than 85 F or lower than 65 F To set the high humidity alarm 1 In normal display press the Plus or Minus key to...

Page 14: ...e Alarm key to enter the high temperature alarm setting To set the high temperature alarm 1 In normal display press the Plus or Minus key to select a temperature humidity sensor the temperature humidi...

Page 15: ...nd 65 F low while only activating high temp alarm and deactivating low temp alarm In this case the alarm will not trigger when temperature is lower than 65 F yet will trigger when temp is higher than...

Page 16: ...ond The maximum and minimum temperature humidity data and the time of record will be reset to the current value CLEARING THE MAX MIN TEMPERATURE AND HUMIDITY DATA OF ALL REMOTE TEMPERATURE HUMIDITY SE...

Page 17: ...minutes followed by the full segment display You are then required to remove and re insert the batteries to complete the restart of the unit After batteries are re inserted the station will automatica...

Page 18: ...ck the following items 1 The distance of the indoor weather station or remote temperature humidity sensors should be at least 6 feet 2 meters away from any interfering sources such as computer monitor...

Page 19: ...t over the desired location 3 Through the screw holes of the bracket mark the mounting surface with a pencil 4 Screw mounting bracket onto the mounting surface Ensure that the screws are flush with th...

Page 20: ...s to the units Return it to their original point of purchase for repair by a qualified engineer Opening and tampering with the units may invalidate their guarantee Do not expose the units to extreme a...

Page 21: ...n your owner s manual 5 damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology Ltd authorized service center 6 units used for other th...

Reviews: