When in any of the above modes, press the MIN/MAX key to toggle
between the maximum or minimum values of those records and their
respective time and dates will also be shown.
For the wind and pressure minimum and maximum readings, the
same would apply except that the WIND or PRESSURE keys would
be used instead of the DISPLAY KEY.
Exiting the MIN/MAX modes
If the maximum and minimum modes with times and dates are dis-
played, press the PLUS (+) key twice to return the normal display
mode.
Resetting the MIN/MAX records
While in the minimum or maximum mode, the time and dates are also
displayed along with the recorded values. If the MINUS (-) key is
pressed while any of these values are displayed, that particular mini-
mum or maximum record will be reset to current reading together with
the current time and date with the exception of the following:
The first case is Rainfall Total, which has neither maximum nor
minimum records since it will show only the total rainfall. Pressing
the MINUS (-) key will reset the rainfall total value to zero and the
time recording to current time.
The second case is Rainfall 24h or 1h, which records maximum
rain count only for these respective times. Pressing the MINUS (-
) key in either of these two modes will reset the rain count to the
current rain count and time and date.
The third case is wind speed, which will only reset the recorded
time to current time when the MINUS (-) key is pressed.
15.
Alarm Programming Modes
Alarm Modes
As well as the normal time alarm, this feature will allow users to set a
range of specific alarms to meet specific weather and temperature
conditions set by the user. The weather station allows for the follow-
ing 13 alarms modes to be set:
1. Time
alarm
2. Indoor temperature high alarm and low alarm
3. Outdoor temperature high alarm and low alarm
4. Indoor humidity high alarm and low alarm
5. Outdoor humidity high alarm and low alarm
6. Wind chill high alarm and low alarm
7. Dew point alarm high alarm and low alarm
8. Rainfall 24h alarm
9. Rainfall 1h alarm
10. Pressure high alarm and low alarm
11. Wind speed high alarm and low alarm
12. Wind direction alarm
13. Storm warning alarm
Setting Alarms:
For alarm setting, press the ALARM key once while in normal opera-
tion mode to enter the normal alarm time and by further pressing the
ALARM key will toggle through each of the alarm modes:
Note:
The alarm icon will automatically appear upon pressing the SET
key to tell the user the alarm is activated. Further pressing the
SET key will deactivate/reactivate the alarm.
Time alarm setting
1) Press the ALARM key to enter the normal time alarm
2) Press and hold the SET key to enter the alarm hour time set
mode (the hour digits will flash) and set the desired hour by using
the PLUS (+) or MINUS (-) keys
3) Press the SET key to enter the alarm minute time set mode (the
minutes digits will flash) and set the desired minutes using the
PLUS (+) or MINUS (-) keys
4) Press ALARM key to confirm followed by the MIN/MAX key to
return to the normal display mode.
Indoor temperature high alarm and low alarm setting
1) Press the ALARM key to enter the normal time alarm
2) Press the ALARM key again to enter indoor temperature high
alarm set mode
3) Press and hold the SET key to enter the indoor temperature high
setting values (digits will start flashing) and set the desired indoor
temperature high by using the PLUS (+) or MINUS (-) keys