background image

 

La Crosse Technology, Ltd.  

Page 16 

 

  The SUNNY icon indicates clear weather, even when displayed during the night-time.The icons 

displayed forecast the weather in 

terms of getting better or worse, and not necessarily sunny or rainy

 

as each icon indicates.  

Note:

 After initial set-up, disregards icons for weather forecasts for the next 48-60 hours. This will allow 

sufficient time for the weather station to collect air pressure data at a constant altitude and result in a 
more accurate forecast. 
 

Moon phase 

 

  The moon phase is based on the year, month and date, set manually or set by the WWVB signal. 

 

New Moon

 occurs when the moon is between the earth and sun, so the illuminated portion of the 

moon is on the backside facing the sun and we cannot see it. After a new moon, the illuminated 
(visible) portion will increase or wax until the full moon occurs. 

 

Full Moon

 occurs when the earth, moon and sun are in approximate alignment with the moon and 

the sun on opposite sides of the earth. The illuminated portion of the moon faces the earth, giving us 
complete visibility of one side of the entire moon. After a full moon, the illuminated portion will 
decrease or wane until the new moon occurs. 

 

First Quarter

 and 

Last Quarter

 moons occur when the moon is at a 90-degree angle to the earth 

and sun. We see half of the moon illuminated and half is in shadow.  

 

Waxing

 means growing or expanding illumination, which occurs after a new moon. 

 

Waning

 means decreasing illumination and occurs after a full moon. 

 

Crescent

 refers to the moon being less than half-illuminated. Crescents can be waning or waxing. 

 

Gibbous

 describes a moon phase when more than half is illuminated. Gibbous can be waxing or 

waning. 
 

Moon phase history 

 

  The weather station indicates the current moon phase. You can view moon phase history and 

forecast for up to 39 days in one-day increments.  

  The history will show in the History Window with a + or 

– number indicating the days of change.  

  The moon icon itself will also change to match the history reading. 

1.  Select the Pressure and Weather Forecast display. 
2.  Press and release the MEMORY button, and 

+ 0

 days will flash.                          

3.  Press the UP or DOWN 

arrow buttons selecting from today’s date a future (+) or past (-) days and the 

corresponding moon phase will be displayed. Hold either arrow button for a quick advance. 

4.  Press the MEMORY button to exit 
 

Backlight 

 

  The weather station includes a light sensor that detects low light conditions and will turn the backlight 

on automatically (A/C power cord use required).  

 

When operating with the optional A/C power cord, the weather station backlight can be turned 
ON, OFF or automatic (depending on light conditions).   

 

AUTO: The backlight will be off in when there is adequate light, and will come on automatically in 
low light conditions.  

 

ON: The backlight will be on constantly when using A/C power. 

 

OFF: The backlight will remain off unless the LIGHT button is pressed. 

Note:

 For continuous backlight control, the A/C adaptor (included) must be plugged in. 

  Adjust backlight sensor sensitivity to high or low using the switch, located on the back of the weather 

station. 

  When operating on battery power alone, press the LIGHT button to activate the backlight for three 

seconds. 
 

Comfort statement 

 
The weather station will calculate the indoor comfort level based on indoor temperature and humidity. 

  COMFORT:  

Indicates the indoor temperature and humidity are in a comfortable range. 

Summary of Contents for WS-1517

Page 1: ...oes not work 4 Thermohygro transmitter drains batteries quickly 5 Outdoor temperature humidity is stuck or OFL 5 Thermohygro transmitter stops working when hot 5 Humidity shows OFL but temperature wor...

Page 2: ...itioning outdoor transmitter 11 Mounting Positioning wind transmitter 11 Mounting Positioning rain transmitter 12 Position weather station 12 Distance Resistance Interference 12 Weather Station 13 12...

Page 3: ...ng segments dim display etc Weather Station Factory Restart 1 ERASE MEMORY Hold the SNOOZE and UP buttons together for about 5 seconds until the backlight flashes Press the SET button to clear the mem...

Page 4: ...hin tolerance The humidity should be within 10 to be within tolerance If the transmitter reads correctly when next to the weather station try a different location outside Look for heat sources such as...

Page 5: ...BATTERIES At higher temperatures batteries can overheat causing transmitter failure Older and weaker batteries are more likely to fail in hot weather Try a fresh set of batteries to see if the issue...

Page 6: ...ly to the weather station It is not dependent on the thermohygro sensor for signal reception 2 AA batteries power the wind sensor Cups spinning slow or not spinning Check for debris or ice in cups Be...

Page 7: ...signal Details are helpful in resolving the problem Check that your batteries are fresh Complete a factory restart Wind speed is inaccurate Check the unit of measure MPH KM H or M S Check to see if th...

Page 8: ...re Bring the transmitter in the house for 2 3 days The transmitter will need to thaw out and dry out for prevent refreezing Wind alerts The weather station provides the option to set Wind Speed Hi ale...

Page 9: ...his is a midnight to midnight measurement The day is a fixed clock time measurement WEEKLY RAIN The amount of rainfall from the previous week The week is midnight Sunday to midnight Saturday MONTHLY R...

Page 10: ...er tips freely Check the funnel and the inside of the rain transmitter for insect nests or debris that may cause loss of rocker motion Check for proper battery installation Check the battery cover is...

Page 11: ...count when the snow begins to melt and run into the rain transmitter This will not be an accurate measurement for snow Mounting Positioning outdoor transmitter First set up everything in the house to...

Page 12: ...rference The rain gauge is self emptying and can be left out all year or stored in the winter If stored for the winter remove the batteries to avoid leakage Position weather station Make sure that the...

Page 13: ...below for a list of available cities 4 Press the SET button to confirm the city selection The year will flash 2005 5 Press the UP or DOWN button to select the correct year 6 Press the SET button to c...

Page 14: ...weekday alarm or single day alarm time 2 If these alarms are not set the abbreviation OFF will be displayed 3 To enable or disable any of these alarms press the UP or DOWN button arrow button 4 Press...

Page 15: ...s press and release the HISTORY button repeatedly to view the sea level pressure history for the past 24 hours in one hour intervals 3 If no buttons are pressed for 5 seconds the weather station will...

Page 16: ...scribes a moon phase when more than half is illuminated Gibbous can be waxing or waning Moon phase history The weather station indicates the current moon phase You can view moon phase history and fore...

Page 17: ...s distorted display On a brand new weather station check for thin plastic films of printed scratch guard that may be on the upper and lower screen of the weather station This thin piece of plastic has...

Page 18: ...y Codes Time zone SEE PAGE 19 Set the Time Zone by selecting a City code in your time zone 1 Press the UP or DOWN arrow button until the clock and alarm icon flashes 2 Hold the SET button until the da...

Page 19: ...ng Nanking China 8 NKG Memphis TN 6 MEM Buenos Aires Argentina 3 BUA Odessa Ukraine 2 ODS Mexico City Mexico 6 MEX Budapest Hungary 1 BUD Omaha Nebraska USA 6 OMA Milwaukee WI 6 MKE Cairo Egypt 2 CAI...

Reviews: