background image

Sensor Placement & Mounting

Cyclone Sensor Mounting

SENSORS

SENSORS

21

22

• 

 Use the hole at the top to hang your sensor from the back using a nail.

Or, insert one mounting screw through the front of your sensor.

• 

 Mount your sensor on a north-facing wall or in a shaded area. Under 

an eave or deck rail is preferred to avoid inaccurate readings from the sun.

• 

 The maximum wireless transmission range to the station is up to 400 feet 

(121 meters) in open air, not including walls or floors.

• 

 Be sure your sensor is mounted vertically, to allow moisture to drain

out properly.

• 

 For online video instruction visit: 

bit.ly/th_sensor_mounting

Fence posts, poles, decks, and mailboxes are common mounting options due to their convenience. 

Many users prefer these types of locations as the data they provides is accurate from their ground 

level. However, because the wind in these spots is often affected by obstructions, the readings may 

differ when compared to local reporting stations.

• 

 Use the built-in Bubble Level to ensure the Cyclone Sensor 

(especially the rain gauge) is mounted level.

•  

Ensure the Solar Panel is facing to the South. This helps 
optimize battery life and transmit correct wind direction data.

•  

Ideally, the Cyclone Sensor should be mounted on the tallest 
object in your area. Avoid positioning the sensor parallel 

or below eaves, roof lines, trees, or other objects that may 

obstruct wind and rain readings.

• 

 Make sure all the screws on the Mounting Bracket, Wind Cups, 

Wind Vane, and Battery Compartment are securely fastened.

• 

 The Cyclone Sensor should be mounted with the Wind Cups

on the top. See page 

02

 for wind cup installation information.

For Accurate Thermo-Hygro Sensor Measurements

Basic Installation

For Accurate Cyclone Sensor Measurements

Bubble Level

Mount the Mast to a flat surface with the four 

provided screws.

Check the integrated Bubble Level or use your own 

across the Rain Funnel to ensure the sensor is level.

Place the Cyclone Pro Sensor on top of the Mast. 

Ensure the Solar Panel is facing south.

Secure the Cyclone Sensor to the Mast by tightening 

the screws on the side. After screws are tightened, 

double check the sensor has remained level

through the installation process.

1.

3.

2.

4.

Summary of Contents for V42

Page 1: ...SET UP GUIDE MODEL NUMBER V42 BP73736 Wi Fi PROFESSIONAL WEATHER STATION...

Page 2: ...al Setup Station Settings Buttons LCD Display Brightness Auto Dim Settings Time Calendar Display Viewing Wind Data Wind Speed Records Customizable Alerts Wind Cup Installation Placement Mounting Rain...

Page 3: ...Play Store to download the free La Crosse View app onto your mobile device Launch the App Connecting Your Station to the App Open the La Crosse View app Follow the on screen setup instructions to cre...

Page 4: ...r account 2 Next the app will prompt you to use your phone to scan the device ID barcode located on the back of the station Please note adding a device to your account and connecting it to Wi Fi are t...

Page 5: ...tings Menu 1 Use the buttons on the top of the station to adjust the values 2 Press the SET button to confirm your selection and move to the next setting 3 You may exit the Settings Menu at any time b...

Page 6: ...to adjust the stopping hour Press LIGHT to confirm and exit Time Calendar Display Data Stream Technology Data Streams allow you to see additional AccuWeather information in the time calendar section...

Page 7: ...ssure over the past 3 hours Viewing Extended Forecast Press and release the FORECAST button to toggle through your next 12 hours and next 7 days of forecast data 12 Rapid Increase Steady Pressure Slow...

Page 8: ...iling Wind Direction over the past hour 13 14 24 Hour Record Example 1 Month Record Example 1 Year Record Example Wind Speed Records When viewing the monthly record press and release the PLUS button t...

Page 9: ...The scale values automatically adjust when over 1 inch 25 4 mm of rain is measured Days Since Last Rain After 24 hours of no rainfall the station will start counting days without rain Rainfall readin...

Page 10: ...station to toggle through rainfall records with time and date stamps See rainfall records for the past hour 24 hours 7 days month year and total since start up Viewing Temperature Humidity Data TEMPER...

Page 11: ...Outdoor Low Humidity 7 Indoor High Temperature 8 Indoor Low Temperature 9 Indoor High Humidity 10 Indoor Low Humidity Records Viewing Order 1 Outdoor High Temperature 2 Outdoor Low Temperature 3 Outd...

Page 12: ...ensure the Cyclone Sensor especially the rain gauge is mounted level Ensure the Solar Panel is facing to the South This helps optimize battery life and transmit correct wind direction data Ideally the...

Page 13: ...installation options include tripods wall mounts chimney mounts and many others Any of these can be combined with U bolts for attachment onto a tall cylindrical conduit using our Adjustable Base Thes...

Page 14: ...endar THERMO HYGRO SENSOR LTV TH5i Outdoor Temperature Range 40 F to 140 F 40 C to 60 C Outdoor Humidity Range 10 to 99 RH Transmission Range 400 feet 121 meters open air Update Interval Every 51 Seco...

Page 15: ...s 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Caution Any changes or modification...

Page 16: ...ons watch setup videos and provide feedback on our social media outlets Scan for Self Help Factory Reset If you are experiencing issues press and hold the ALERTS and RAIN buttons down together until t...

Reviews: