background image

La Crosse Technology, Ltd.            www.lacrossetechnology.com/support 

Page 2 

 

Manually Set Time/Date:  Program Menu

 .....................................................................10 

Forecast Icons Inaccurate

 ................................................................................................11 

Weather station is dim

 ......................................................................................................12 

Weather station has distorted or frozen display

 ...........................................................12 

Weather station is blank: No letters, numbers or dashed lines

 ................................12 

Weather station drains batteries quickly

 .......................................................................12 

Weather station has missing segments

 .........................................................................12 

 

AC Power 

 

 

The design of this weather station is to use AC power (5-volt) as primary power source. 

 

When operating with the AC power cord, the 

backlight 

can be on continually.  

 

When operating on AC power, batteries are optional and are not required in the weather 
station. 

 

The 

backlight

 

will turn off or operate at high or low intensity at your discretion. 

 

Batteries 

 

Explanation:

 Many problems are resolved with fresh batteries of the appropriate voltage. 

Many items sent in under warranty work when tested with fresh batteries. Batteries 
manufactured this year will have an expiration date 10 years (or more) in the future. 
Battery technology has improved and batteries will maintain voltage longer in storage. 
However, the environment the batteries reside in for the 10 years can deplete the power. 
 

 

Use Alkaline or Lithium batteries in the 

remote sensor.

 

 

A minimum voltage of 1.48V for each battery is necessary for proper performance.   

 

Use batteries dated at least six years in advance of the current year. Batteries dated 
earlier than six years from now may still work, but may be unstable in performance.   

 

Good name brand batteries make less noise, which reduces the chance of RF (radio 
frequency) interference from the battery compartment.  

 

  Weather Station Factory Restart 

 

Explanation:

 The factory restart returns the weather station and remote sensor to an “out-

of-the-box” default state and often resolves an issue.  

  

Factory Restart: 

1.

 

Remove all power (batteries and AC) from remote sensor and weather station.  

2.

 

Press one of the buttons on the weather station at least 20 times to clear all memory.  

3.

 

Verify that the weather station is blank before proceeding (there may be lines painted on 
the screen that will show when there is no power). 

4.

 

Leave both units without power for 15 minutes

 (very important). 

5.

 

Insert the AC power cord into the wall outlet then into the weather station.  

6.

 

Insert fresh batteries into the remote sensor. 

7.

 

Press the TX button on the remote sensor to transmit RF signal.   

8.

 

Keep the remote sensor 5-10 feet from the weather station. 

9.

 

When RF connection is established, the temperature will appear on the station. Allow the 
remote sensor and weather station to sit together for 15 minutes to establish a strong 
connection.  

10.

 

Do not press buttons for 15 minutes. 

 

For optimum 433MHz transmission, place the remote sensor no more than 300 feet (91 
meters, open air) from the weather station. 

 

See the section on 

mounting 

and 

distance/resistance/interference 

for details on 

mounting the remote sensor. 
 

 

Summary of Contents for 308-1414M

Page 1: ...ermittent Remote Temperature 4 Remote Temperature is stuck or HH H LL L 4 Remote sensor drains batteries quickly 4 Remote Humidity goes to dashes when temperature is cold 5 Remote sensor fell The sens...

Page 2: ...dvance of the current year Batteries dated earlier than six years from now may still work but may be unstable in performance Good name brand batteries make less noise which reduces the chance of RF ra...

Page 3: ...splay will be dashes If synchronization fails once the antenna will lose one bar If synchronization fails twice the antenna will lose two bars If RF radio frequency reception fails five times the ante...

Page 4: ...ote temperature area move the remote sensor to another room with one wall between the remote sensor and the weather station Observe to see if the temperature remains on consistently for 1 hour If the...

Page 5: ...sors Visit your local Retailer or La Crosse Technology Store http store lacrossetechnology com Note Be sure to order the correct model and frequency to avoid receiving the incorrect item Call La Cross...

Page 6: ...e condensation The higher the dew points the higher the moisture content of the air at a given temperature View Dew Point Temperature From the default time display press the HEAT DEW button twice and...

Page 7: ...emote sensor onto the screw hanging hole on the backside Gently pull down to lock the screw in place Option 2 Insert the mounting screw through the front of the remote sensor and into the wall Tighten...

Page 8: ...avel through a hill Temperature Alerts Explanation The remote and indoor temperature alerts are set in two separate steps Set the alert value Arm Disarm the alert Select Temperature Alert Values Hold...

Page 9: ...light OFF Press the HI LOW OFF button again to turn the backlight off Press the HI LOW OFF button to return to full strength Note When the backlight is off press any button to activate the backlight f...

Page 10: ...OW OFF button to snooze the alarm for 10 minutes The snooze option can repeat three times The alarm icon will flash while the snooze feature is active Note while the alarm sounds press any button exce...

Page 11: ...s and release the or buttons to select the correct month Confirm with the TIME SET button and move to the date 9 DATE The date will flash Press and release the or buttons to select the correct date Co...

Page 12: ...s generally a power related issue Batteries may be overpowered or underpowered Remove batteries from weather station Press any button 20 times Leave the batteries out of the display for 2 hours Insert...

Reviews: