CONNECTIONS
52
Installation Guide - "Château" Range G4
08NOTINSTALG4/EN-1
Electrical connections
La Cornue appliances are supplied with 1 – 3 flexible cords, P/N: H07 RN-F, consisting of
3 or 5 wires, approximately 1.5 m long, ready to be connected to a single-phase or 3-phase
+ n ground power supply, depending on the indications specified on the order form
(see the table corresponding to each model for the power ratings).
The overall wattage of your appliance is also indicated on the rating plate and on the
warranty certificate (See pt.4, page 13 for the location of the plate).
If the wire is damaged, it must be replaced by the manufacturer, its after sales
services or qualified persons in order to avoid hazard.
All of the electricity supply circuits must be disconnected before accessing the
connection terminal boxes.
REMINDER: the appliance should be connected to the main power supply via terminal
blocks and not by means of simple plugs.
Insert the cable below the hot air outlets at the back of the oven, never in front of them.
Should your appliance be connected to a different type of power supply at a later date, in
some cases (please contact our technical department before) it will be possible to change
the cabling accordingly, according to the following instructions:
- Open the connection box on the back of the appliance using a flat-head
screwdriver. Press the screwdriver horizontally into the slots on the left and right below
the box and push up the latches in the box cover. Remove the cover.
- Access the connection terminal blocks(es) to which the various heating elements
are connected (if there are 2 or 3 supply cables on the cooker, there will also be 2 or 3
connection terminal blocks).
1. E
LECTRICAL CONNECTIONS
C
ONNECTIONS
Connection box
Opening the connection box