53
Installation Guide - "Château" Range G4
08NOTINSTALG4/EN-1
CONNECTIONS
Electrical, Gas connections
- For a
single-phase 220 - 240 V
power supply, shunt the P1, P2 and P3 terminals
with shunt assemblies (1), and then connect the cable wires as follows:
- neutral (blue wire) to N
- the phase (red or brown wire) to P1
- the ground to T (yellow / green)
- For a
3-phase 400 V
power supply, remove the shunt from the P1, P2 and P3
terminals, replace them (1) and then connect the cable wires as follows:
- neutral (blue wire) to N
- the three other wires (red or brown) to the P1, P2 and P3 terminals.
- the ground to T (yellow / green)
- Securely attach the cable with the cable clamp (2).
Ensure that the cross-section of the electrical cables corresponds to that
indicated in the tables in the general description for each appliance.
Our appliances are supplied with injectors corresponding to the type of gas supply specified
in your order (natural gas, butane or propane). These injectors should only be changed if
a different type of gas is used.
However, it may be necessary to adjust or change the "by-pass" screw.
See page 67 for the table summarising the injectors to be used for each type of gas, the
country of installation and injector replacement instructions.
If no particular instructions are specified in the order, the appliance is equipped with
injectors for natural gas G20, pressure 20 mbar.
The type of gas for which the appliance is equipped is indicated on a label at the back
of the hob, close to the gas supply pipe and on the test certificate supplied with the
appliance.
2. G
AS CONNECTION
220-240 V a.c. – single-phase
400 V a.c. – 3-phase
1
P1
P3
P2
N
N
2
T