46
Installation Guide - "Château" Range G4
08NOTINSTALG4/EN-1
Safety requirement
BEFORE DELIVERY
"La Cornue" can propose you models of customized hoods in materials matching your
cooker or extractors that can be integrated into a hood manufactured by the user.
The ventilation hood has to be built with non-combustible materials.
For optimum efficiency, the fresh air inlet for renewing the air extracted by the hood must
be located either directly at the back of the appliance or within a 2 – 3m. radius, at ground
level.
MINIMUM DISTANCE FROM THE KITCHEN UNITS (in mm.)
1.2. Installation (see above)
As the oven and the hob are particularly well insulated, the appliance can be built-in
without any need for any special precautions with regard to the surroundings.
However, if the cooker or the cooktop is installed against a wall, the hottest parts
(the strip between 60 and 95cm. from the floor, and the surface between the
cooktop and the extractor hood) must be protected with a stainless steel plate or
ceramic tiles.
La Cornue is able to offer you several backsplash (stainless steel plate) at
dimensions according to your stove.
Ceramic cardboard with a minimum thickness of 20mm. must be installed under
the cooktop to insulate the units placed underneath.
RECOMMENDED 900
MINIMUM 750