IGNITION
Injectors
Installation guide “Broche Flamberge” Centenai
r
e
08NOTINSTBFG100/FR – 1
17
Warning: Make sure that there is enough room between the lever and the lower plate to
allow the lever to be pressed down before turning when lighting the burner.
3. I
NJECTOR REPLACEMENT
All by-pass screw and injector replacements and adjustments should be
carried out by a qualified professional.
The bu rn er i nject or referen ce di ffers acco rdin g t o th e t yp e of gas and co unt r y o f
installation.
The following table indicates which injectors should be used following a change in the gas
supply or a house move.
GAS
Injector
BY-PASS SCREW
Categories
index
Pressure of
reference
gas
COUNTRY
Diameter
(mm)
Marking
Primary air
adjustment(
mm)
Marking
Adjustment
2E+
G20/G25
20/25 mbar
BE, FR
2H
G20
20 mbar
AT, CH,
CY, CZ,
DK, EE,
ES, FI,
GB, GR,
HR, IE,
IT, LT,
LV, NO,
PT, RO,
SE, SI,
SK, TR
2E
G20
20 mbar
DE, LU,
PL
2,3
230
3
96
Adjustment
2L
G25
25 mbar
NL
2.4
240
2
96
Adjustment
N
A
T
U
R
A
L
2LL
G25
20 mbar
DE
2.6
260
2
96
Adjustment
3+, 3B/P,
3B, 3P
G30/G31
28-30/37
mbar
BE, CH,
CY, CZ,
DK, EE,
ES, FI,
FR, GB,
GR, HR,
HU, IE,
IT, LT,
LU, LV,
NL, NO,
PL, PT,
RO, SE,
SI, SK, TR
1.5
150
6
96
Screw
completely in
B
U
T
A
N
E
–
P
R
O
P
A
N
E
3B/P, 3B,
3P
G30/G31
50 mbar
AT, CH,
DE, LU,
SK
1.25
125
2
80
Screw
completely in
Country:
AT: Austria
ES: Spain
IE: Ireland
PL: Poland
BE: Belgium
FI: Finland
IT: Italy
PT: Portugal
CH: Switzerland
FR: France
LT: Lithuania
RO: Romania
CY: Cyprus
GB: United Kingdom
LU: Luxemburg
SE: Sweden
CZ: Czech Republic
GR: Greece
LV: Latvia
SI: Slovenia
DE: Germany
HR: Croatia
NL: Netherlands
SK: Slovakia
DK: Denmark
HU: Hungary
NO: Norway
TR: Turkey
EE: Estonia