Safety
BEFORE DELIVERY
Installation guide “Broche Flamberge” Centenai
r
e
08NOTINSTBFG100/FR – 1
10
In order to be able to install your appliance as soon as it is delivered, you must check that
the layout of your kitchen and your gas and electricity supplies are adapted.
All gas and electrical installations must comply with the standards and regulations
in force in the country where the appliance is installed, as well as with the
requirements of local gas and electricity suppliers.
In the event of the rotisserie being installed by us, our technicians may ask you for a
certificate proving that your domestic installation is compliant.
The manufacturer shall not incur any liability for an incorrect installation, and incorrect
installations shall void the warranty. Moreover, no legal actions can be undertaken in
relation to incorrect installations.
1. SAFETY
1.1. Ventilation
Special care should be taken to respect the regulation in force regarding ventilation.
All requirements and regulations in force regarding the ventilation of rooms where
gas appliances are installed, should be respected.
The “Broche Flamberge” spit is not intended to be connected to a ventilation shaft or
ventilation system for combustion products leading to the outside. It is therefore vital that
the room where the spit is to be installed has
excellent ventilation, i.e. to the outside
- for hot air, vapor and burnt gases – and
a fresh air inlet
.
Any room where a gas appliance is installed must have general, continuous ventilation, subject
to the ventilation rates being compatible with the fresh air flow rates required for correct
operation of the appliances.
You should take into account all appliances using gas installed in the room; additional
ventilation may be necessary.
Do not use an air recycling system
A flow rate of at least 4 cubic meters per hour of fresh air per KW of gas heat power is
necessary to guarantee an adequate combustion air supply.
The external evacuation system
must consist of fixed aerators, flipping glass panes,
vapor extractors or extractor hoods
. We advise you to adopt one of the latter two
solutions.
BEFORE DELIVERY