Adjustments
IGNITION
Installation guide “Broche Flamberge” Centenai
r
e
08NOTINSTBFG100/FR – 1
16
2. ADJUSTMENTS
All adjustments are made before leaving the factory to ensure an optimal setting. However, after
changing an injector for use with a different type of gas supply, the “low” flame setting
should be adjusted.
All settings and injector replacements should be carried out by a qualified
professional.
After any intervention on the gas circuit (adjustments, injector replacements,
etc) the system should be checked for gas sealing tightness, according to current
standards.
2.1. Adjusting the “low” flame setting
Only the burner “low flame” setting can be modified by the following procedure:
1. Remove the control lever by unscrewing the screw(a)
which holds it in place.
2. Remove the lower plate by unscrewing the screws (b)
blocking it.
3. Re-install the control lever; light the burner and turn the
lever to the “low flame” position.
4. Remove the control lever again and using a screwdriver, turn
the slotted screw (A) located on the body of the tap (B) to th e
left to increase
the gas flo w or to th e
right to reduce
it.
Re-install the lever to switch off the burner.
Comment:
the flame height must not be more than a third of
the height of the hearth.
5. Re-install the lower plate and the control lever, tightening the appropriate screws
a
b