INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
34
Burner head
Burner base
Brass venturi
Important
•
Observe all governing codes and ordinances.
•
The range must be properly grounded.
•
Save these instructions for the local electrical inspector’s
use.
When servicing or replacing gas carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion. When
checking for gas leaks use a liquid leak detector at all joints
and connections to check for leaks in the system. Use a
product specifically manufactured for leak detection. Leak
testing of the appliance shall be conducted in accordance to
the manufacturer’s instructions.
For Your Safety
DO NOT store or use combustible materials, gasoline or other
flammable vapors and liquids in the vicinity of this or any
other appliance.
Conversion to Propane
This appliance is supplied set for Natural gas. A conversion kit
for Propane gas is supplied with the range.
If the appliance is to be converted this must be done before
installation. The conversion must be performed by a qualified
LP gas installer. After conversion the installation must comply
with the relevant regulations and also the local electricity
supply company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest
of the appliance instruction, in particular for information on
Standards, range positioning, connection hose suitability etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
DO NOT use reconditioned or unauthorized gas controls.
Orifices
Remove the burner heads. Undo the large brass nuts and
remove the brass venturis and rings
(Fig.7-1)
.
Either:
Use a long socket wrench to access and remove the old
orifices.
Or:
Lift up the front of the maintop and prop it up at the
front. Remove the old orifices.
Save the orifices removed from the appliance for future use.
Install the new orifices; see
Table 7-1
for orifice details.
7. Conversion to LP Gas
Natural Gas
Propane Gas
Center burner
205
118
Large Burners
150
99
Right front burner
112
68
Fig.7-1
Table 7-1