INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
26
ArtNo.280-0041 - Strain relief bracket 3-wire
ArtNo.280-0040 4 Wire Conduit Fitting
ArtNo.280-0039 Reducer Plate
ArtNo.280-0081 - 4 Wire
conduit terminal connection
Black
White
Red
Green
Ground
Fig.6-21
Fig.6-22
4-Wire Conduit Installation
Disconnect the supplied power cord from the terminal block
and ground post. Keep the terminal block parts; you will need
them. Remove the strain relief clamp from the power cord
and remove the power cord and strain relief clamp from the
mounting bracket
(Fig.6-21)
.
The range is shipped with reducer plates to give a 1
1
/
8
’’
diameter opening for conduit connection. Find the reducer
plates
(Fig.6-22)
in the conversion kit and fix them to the
mounting bracket.
Attach a squeeze connector (not supplied with the range) to
your conduit. Insert the conduit through the reducer plates
on the mounting bracket. Allow enough slack to easily attach
the wires to the terminal block.
Note:
Do not install the conduit without a squeeze connector.
Attach the wires to the ground post and terminal block
(Fig.6-23)
.
Note:
Make sure the wires are completely inserted into the
terminals and secure connections are made.
Secure the squeeze connector in place in the bracket by
tightening the squeeze connector screws.
Replace the electrical connection cover.
Installing a 3-Wire Power Cord
Disconnect the supplied power cord from the terminal block
and ground post. Keep the terminal block parts; you will need
them. Remove the strain relief clamp from the power cord
and remove the power cord and strain relief clamp from the
mounting bracket. Discard the strain relief clamp.
Note:
Do not install the power cord without a strain relief
– use the clamp supplied with the cord.
Install the new strain relief device to the mounting bracket by
removing the two clamping screws, feeding the two halves
(ears first) through the hole in the mounting bracket and
loosely replacing the screws. Insert the power cord through
the strain relief device but do not tighten the device yet
(Fig.6-24)
.
A ground strap is supplied in the conversion pack
(Fig.6-25)
.
Attach the ground strap to the ground and center terminal of
the connector block
(Fig.6-26)
.
The neutral or ground wire of the power cord must be
connected to the neutral terminal located in the center of the
connector block. The power leads must be connected to the
outside terminals.
Make sure the connections are tight. Now tighten the strain
relief device to clamp the power cord.
Refit the electrical connection cover.
ArtNo.280-0082 - 3-Wire conduit connection
Strain relief
device
White
Black
Red
‘Ground strap’
Ground
ArtNo.280-0042 Ground Strap
Fig.6-24
Fig.6-23
Fig.6-25