BPA10T30W100
Broadband System User Manual
E-Mail: [email protected]
www.l2microwave.com
- 11 -
3.
Installation
This chapter describes the installation of the BPA10T30W100 broadband amplifier and the requirements for
the peripheral infrastructure.
3.1.
Installation Position Selection
RF Radiation
The BPA10T30W100 is a broadband amplifier that generates electromagnetic waves and may affect other
sensitive equipment; therefore, should only be operated in an industrial environment.
Installation position
This equipment uses air circulation cooling method using FAN to release heat by high power operation.
Therefore, we recommend installation in a spacious space with no dust or other contaminants.
Others
The operator of the BPA10T30W100 should not be disturbed during operation of the broadband amplifier
system.
The recommended power of the BPA10T30W100 is 1.6kW or more.
We recommend installation only in
places where breakers and electric power facilities are 1.6kW or more.
3.2.
Transport and Moving
Avoid product damage (damage) caused by improper transportation. Improper transport can cause
the product to fall or fall, causing serious damage to the equipment.
• Broadband amplifiers must be installed with L2 Microwave or qualified personnel, although they may vary
depending on the equipment.
• Do not disassemble or move the installed broadband amplifier arbitrarily.
• When moving with forklifts and other lifting machines, the broadband amplifier should not tilt to one side
and move carefully to avoid affecting the internal parts. If it is tilted to one side, it may fall over, causing
internal or external damage to the rack.
3.3.
Power Supply
The BPA10T30W100 wideband amplifier system operates with the following AC voltages
.
-
Acceptance input voltage :
AC 220V single phase
-
Maximum power consumption : 1.6 kW
-
Power frequency : 47 Hz ~ 63 Hz
3.4.
Load Condition for System Output
In general, the most defects in broadband amplifier operation are caused by high VSWR of load. Be sure to
check the conditions for the amplifier load as shown below.