4.
Operation method
This chapter describes the operation and condition of the amplifier.
The AMP ON / OFF button on the front panel operates the amplifier and checks the condition of the amplifier.
If an error occurs in the amplifier, the Alarm LED on the front panel will change to RED and the amplifier will go off.
To reactivate the amplifier, remove the cause of the alarm and operate by pressing the AMP ON / OFF button again.
4.1.
Equipment operating sequence.
To control the amplifier, follow by below sequence for system operation.
①
Plug in rear power switch ON.
-
Use power cable that can supply more than 1.6kW.
-
Connect to ground wire between amplifier and installation site using M3 Nut.
-
Turn on the power breaker.
②
Check the status of the front panel of amplifier.
(Refer to “4.2 Alarm and Description for Status LCD”)
③
Press the “AMP ON/OFF” push button. From OFF mode to ON mode.
④
Input the RF input signal.
- Slowly increase the input value from the -20 dBm input to the target output.
The system is off in reverse order.