14. Make sure the heater has the proper gas regulator for
the application. A regulator must be connected to the
gas supply so that gas pressure at the inlet to the gas
valve is regulated within the range specified on the
dataplate at all times. Contact your gas supplier, or
the L.B. White Co., Inc. if you have any questions.
15. This heater is configured for use with propane gas
vapor withdrawal only. Do not use the heater in a
propane gas liquid withdrawal system or application. If
you are in doubt, contact the L.B. White Co., Inc.
16. Eventually, like all electrical/mechanical devices, the
thermostat can fail. Thermostat failure may result in
either an underheating or overheating condition which
may damage critical products and/or cause animal
injury or death. Critical products and/or animals
should be protected by a separate back-up control
system that limits high and low temperatures and also
activates appropriate alarms.
17. Take time to understand how to operate and maintain
the heater by using this Owner’s Manual. Make sure
you know how to shut off the gas supply to the building
and also to the individual heater. Contact your fuel
gas supplier if you have any questions.
18. Any defects found in performing any of the service or
maintenance procedures must be eliminated and
defective parts replaced immediately. The heater
must be retested by properly qualified service
personnel before placing the heater back into use.
HANGING INSTRUCTIONS
A. Hanging Kit Assembly (See Fig. 1a and 1b)
1. Position mounting supports within base legs of heater
so holes in support and base align.
2. Install the 10-24 x 1/2 machine screws through base
leg and mounting support. Secure in place with 10-24
nuts.
3. Assemble eye bolt, nut, and washers to center hole of
hanging strip. Tighten the nuts securely.
4. Remove two case top screws and nuts directly across
from each other.
5. Align hood support holes with screw holes.
6. Reinstall case top nuts and screws so strip is attached
to case top. Tighten nuts and screws securely.
FIG. 1a
Assembly View
FIG. 1b
Completed View
B. Hanging the Heater
1. Observe and obey all minimum safe distances to the
nearest combustible materials. Minimum safe
distances are given on the heater’s data plate and are
as follows:
-- Top to Ceiling: 5 Ft. 10 In.
-- Sides: 4 Ft.
-- Botton: 4 Ft.
2. Ensure the heater is properly positioned before use
and is hung level.
3. See Fig. 2 on Page 10 for a typical PALS indoor
installation. In any animal confinement building,
consideration must be given to making sure the
heater is located away from livestock so that livestock
cannot knock the heater, tear it loose from its
mounting, or damage the heater, its power supply
cord, or gas supply line in any way.