background image

REGULATOR

GAS SUPPLY

SEDIMENT TRAP

GAS SHUT-OFF

GAS HOSE TO
HEATER INLET

REGULATOR VENT

BUILDING GAS SUPPLY
TO REGULATOR

PROPANE GAS SUPPLY

CONTAINER VALVE

REGULATOR

HOSE

TO

 HEA

TER

ATTENTION

Always use approved pipe thread compound suitable for

use with propane gas or natural gas.

Tighten all connections securely and check them all for

gas leaks using approved leak detectors.

The following views show general assembly of the

components.

The regulator must be installed so its vent, regardless of

regulator design or vent location, is always pointed

downward.

A. Installations using single stage regulators.  See Fig. 3.

-- This shall only be accomplished on installations

where a single heater’s gas regulator is intended

to be connected to:

-  A single 100 lb. cylinder

-  A manifolded set of 100 lb. cylinders

(Up to 3 cylinders maximum)

-  ASME Tank (500 Gallon 1,000 Gallon)

-- This type of regulator installation is typically

associated with heaters utilized in a construction

application.

FIG. 3

B. Installations using two stage regulation.

-- Connect the hose to a second stage regulator as

shown in Fig. 4 when two stage regulation is

required.  Make sure the regulator’s vent is

positioned down.

-- Two stage regulation is used when a constant gas

supply pressure (typically 5-10 PSI) is required for

multiple heaters at an installation.

-- This type of installation is typically associated

with heaters applied within an agriculture

confinement building.

FIG. 4

GAS HOSE

CEILING

CHAIN OR CABLE*

SCREW

HOOK*

SAFETY CHAIN*

EYE BOLT

HEATER TOP

5 Ft. 10 In.

STEEL ROD*

HOOD SAFETY SUPPORT

STEEL RODS*

(45")

4 Ft.

ALL SIDES

GAS SUPPLY
SUPPORTED
TO CONFINEMENT
BUILDING STRUCTURE

GAS SHUT-OFF

SEDIMENT
TRAP

*CUSTOMER SUPPLIED

4 Ft.

WALL OR

ST

ANCHION

POWER

 CORD

LITTER

FIG. 2

9

HOSE AND REGULATOR ASSEMBLY

Summary of Contents for PALS

Page 1: ...d is listed and approved as a direct gas fired convection construction heater with intended use for primarily the temporary heating of buildings under construction alteration or repair As an alternati...

Page 2: ......

Page 3: ...l injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or burns Property damage or...

Page 4: ...ifications Contact PALS Wilmar Poultry at 1 800 328 8842 or the L B White Co Inc for assistance or if you have any questions about the use of the equipment or its application The L B White Co Inc has...

Page 5: ...ES 4 ft BOTTOM 4 ft GAS 6 ft SUPPLY 1 83 m 32 F 16 19 CV250 Propane Natural Vapor Gas M Mo od de el l Ventilation Air Required to Support Combustion CFM Net Weight lbs Shipping Weight lbs Inlet Gas Su...

Page 6: ...y trained service people must repair the leak check for further leakages and then relight the appliance for you WARNING Do not use this heater for heating human living quarters Do not use in unventila...

Page 7: ...r 8 Do not block air intakes or discharge outlets of the heater Doing so may cause improper combustion or damage to heater components leading to property damage or animal loss 9 The hose assembly shal...

Page 8: ...in six feet 6 ft of the heater it serves 10 Check all connections for gas leaks using approved gas leak detectors Gas leak testing is performed as follows Check all pipe connections hose connections f...

Page 9: ...res must be eliminated and defective parts replaced immediately The heater must be retested by properly qualified service personnel before placing the heater back into use HANGING INSTRUCTIONS A Hangi...

Page 10: ...f 100 lb cylinders Up to 3 cylinders maximum ASME Tank 500 Gallon 1 000 Gallon This type of regulator installation is typically associated with heaters utilized in a construction application FIG 3 B I...

Page 11: ...ond trial for ignition If burner flame is not established the igniter will stop sparking and the heater will shut down To recycle the heater for ignition Position On Off switch to Off and then back to...

Page 12: ...able vapors a and l liquids 3 Regulators can wear out and function improperly Have your gas supplier check the date codes on all regulators installed and check delivery pressures to the appliance to m...

Page 13: ...Disconnect the electrical leads from the On Off switch 2 Remove the rubber boot from the On Off switch See Fig 6 3 Remove the switch from the control box FIG 6 IGNITION CONTROL VOLTAGE REGULATOR NUT...

Page 14: ...OR 1 Open access door on barrel 2 Remove retaining pin and side panel from main burner assembly See Fig 12 3 Disconnect flame sensor and ignition leads Remove nuts and screws 4 Remove heat shield and...

Page 15: ...burner orifice from heater 6 Remove burner orifice from manifold 7 Position the orifice as shown in Fig 11 FIG 11 GAS CONTROL VALVE 1 Remove gas hose from heater 2 Remove control box cover and solenoi...

Page 16: ...section of this owner s manual 2 Does the pressure reading agree with that given on the dataplate If so no further checking or adjustment is required Proceed to section D 3 If the pressures does not...

Page 17: ...ied by the flow chart OPERATION SEQUENCE A call for heat occurs from building thermostat 24 Volts D C is sent from building s temperature control to heater s voltage regulator Voltage regulator reduce...

Page 18: ...pplying 12 Volts D C to Ignition Control Check Switch for Continuity Replace if Defective No 17 Is Fuse in Heater Receiving Proper Voltage Incoming Power Supply Should be 18 30 Volts D C Repair as Nec...

Page 19: ...ifice Clean Check the Lead for Corroded Terminals Loose Connections Repair or Replace as Necessary No No No Clean the Orifice Yes Is Sensor Reasonably Clean Properly Gapped Clean Sensor with Emery Clo...

Page 20: ...E BLUE BLACK HIGHVOLTAGE IGNITION LEAD CASE GROUND IGNITOR FLAME SENSOR ELECTRICAL CONNECTION DIAGRAM IF ANY OFTHE ORIGINALWIRES AS SUPPLIEDWITHTHE HEATER MUST BE REPLACED IT MUST BE REPLACEDWITHWIRIN...

Page 21: ...e Component that houses an electromagnet which is energized by voltage and therefore opens or closes to supply or close off the flow of gas to the burner Gas Hose Flexible connector used to convey gas...

Page 22: ...cation PARTS SCHEMATIC 24 35 34 22 36 37 33 32 30 27 23 26 25 53 50 41 45 29 28 31 49 43 44 38 51 52 55 54 14 17 48 40 39 18 15 8 10 5 4 56 57 13 11 12 3 6 9 16 20 19 2 46 7 21 47 42 1 29 5 17A 10A 1...

Page 23: ...ssembly 22641 19 Fuse Holder 21653 20 Cap Fuse 21655 21 Terminal Block 22296 22 Ignition Lead 22651 23 Cord Power 22653 24 Switch Toggle 22714 25 Holder Fuse 22762 26 Fuse 1 5 Amp 250 V 22763 27 Boot...

Page 24: ...d date o of p purchase b by the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months late...